Optical Performance of RayOne EMV and Tecnis Synergy Under Varying Pupil Sizes and Corneal Aberrations
Juan J Miret1, Vicente J Camps1, Celia García1
1Department of Optics, Pharmacology and Anatomy, University of Alicante, 03690 San Vicente del Raspeig, Spain.
Abstract:
Background/Objectives: Premium intraocular lenses (IOLs) are increasingly being selected for cataract and refractive lens surgery, but their functional performance depends critically on pupil size and corneal spherical aberration (SA). This study evaluates how these factors modulate the optical behavior of the RayOne EMV and Tecnis Synergy using a profilometry-based Through Object modulation transfer function (TO MTF) analysis. Methods: The surface profiles of the RayOne EMV and Tecnis Synergy were measured with a confocal optical profilometer and implemented in pseudophakic eye models via ray tracing. TO MTF at 50 cycles/mm was computed for object vergences from -4.0 D to +2.0 D over entrance pupil diameters from 2.0 to 5.5 mm in three corneal configurations derived from the Liou-Brennan model and ISO recommendations: mean population SA, aberration-free, and a myopic LASIK-like oblate cornea. Simulated optotype images were generated to relate TO MTF values to the expected distant, intermediate, and near visual performances. Results: RayOne EMV delivered high-quality distant image performance in all models. Its depth of focus increased only modestly and showed a strong dependence on pupil size. Intermediate and near vision rarely reached clinically acceptable levels. The Tecnis Synergy produced a broad depth-of-field plateau in distant to near visual performance for mean population spherical aberration at a 3.5 mm pupil. However, image quality at 90 cm remained limited. Optical performance worsened with increasing pupil size and positive spherical aberration, particularly under post-myopic LASIK conditions. Conclusions: The RayOne EMV behaves predominantly as a distance-oriented design with minimal true presbyopic benefit; the Tecnis Synergy provides a wider range of vision but is highly sensitive to corneal spherical aberration and pupil size, so thorough preoperative evaluation of corneal asphericity and functional pupil diameter is essential for IOL selection and power targeting.
More Related Videos
07:26Assessing Pupil-linked Changes in Locus Coeruleus-mediated Arousal Elicited by Trigeminal Stimulation
Published on: November 26, 2019
04:48Establishing a Severe Corneal Inflammation Model in Rats Based on Corneal Epithelium Curettage Combined with Corneal Sutures
Published on: November 22, 2024
Related Concept Videos
Gradually Varying Flow
Rapidly Varying Flow
Cell Size
Surface Area
Cells can take in nutrients and water via diffusion through the plasma membrane itself or through specific channels in the membrane. The area of the membrane surrounding...
Brick Sizes
Modular bricks are the most common type and are sized to include the mortar joint, which is essential for...
Genome Size and the Evolution of New Genes
Maximum Size of Aggregate