Agreement and Reliability Between Urine Reagent Strips and Refractometry for Field Assessment of Hydration in
Daniel Rojas-Valverde1,2, Volker Scheer3, Marcelo Tuesta4,5
1Centro de Investigación, Desarrollo e Innovación en Salud y Deporte (CIDISAD), Escuela Ciencias del Movimiento Humano y Calidad de Vida (CIEMHCAVI), Universidad Nacional, Heredia 86-3000, Costa Rica.
Abstract:
Background/Objectives: Accurate hydration assessment is critical for optimizing performance and preventing heat-related complications in ultra-endurance athletes. This study evaluated the agreement and reliability between urine reagent strips and refractometry for field-based hydration assessment via urine-specific gravity (USG) in ultra-trail runners. Methods: Thirty-four ultra-trail runners (22 males, 12 females; mean age 43.71 ± 11.50 years) participated during The Coastal Challenge, a 241-km multi-stage ultra-trail competition. Urine samples were collected before and after the first two stages (Stage 1: 41 km, 1071 m elevation; Stage 2: 40 km, 1828 m elevation). USG was measured using semi-quantitative urine reagent strips (Combur10Test M) and a handheld digital refractometer (Palm Abbe™). Agreement was assessed via paired t-tests, Pearson and Spearman correlations, intraclass correlation coefficients, and Bland-Altman plots across four measurement time points. Results: Strong agreement existed between methods with correlation coefficients of 0.92-0.99 (p < 0.01) within the hydration range typical of well-prepared ultra-endurance athletes (USG 1.010-1.020). No significant differences were found between devices at any time point (all p > 0.05). Bland-Altman analyses revealed minimal mean bias (range: -0.002 to +0.001 g/mL) and narrow limits of agreement, with fewer than 5% of values falling outside limits. Both methods detected significant increases in USG from pre- to post-stage (p < 0.01), indicating exercise-induced hypohydration. Conclusions: Semi-quantitative urine reagent strips and handheld refractometers demonstrate strong agreement for hydration assessment in ultra-trail runners under field conditions when not severely hypohydrated, supporting their interchangeable use for practical monitoring.
Related Concept Videos
Filtration and Urine Formation
Hydration of Cement
Reliability and Validity
Aqueous Solutions and Heats of Hydration
When ionic compounds dissolve in water, the ions in the solid separate and disperse uniformly throughout the solution because water molecules surround and solvate the ions, reducing the strong electrostatic forces between them. This process...
Urine Studies II: Urine Culture and Sensitivity Test
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...