Reliability of Ultrasonography to Assess Spinal Compression During Heavy Load Carriage.
Sherrilyn Walters1,2,3, Ben Hoffman1,4, Celeste E Coltman5
1School of Health and Medical Sciences University of Southern Queensland Ipswich Queensland Australia.
JOR Spine
|February 13, 2026
Summary
Ultrasonography reliably measures lumbar spine changes under load. This low-cost method can assess spinal compression in occupational and clinical settings, aiding in injury prevention.
Area of Science:
- Biomechanics
- Musculoskeletal imaging
- Occupational health
Background:
- Back pain and spinal injuries are major causes of early retirement in physically demanding jobs.
- Practical spinal assessment methods are crucial for evaluating interventions that reduce spinal loading and injury risk.
- While ultrasonography is used for disc height, its reliability for measuring inter-transverse process distances under load is unproven.
Purpose of the Study:
- To establish the reliability of ultrasonography for measuring lumbar inter-transverse process distances under various loading conditions.
- To determine if loaded standing affects lumbar spine geometry as measured by ultrasonography.
Main Methods:
- Eleven healthy adults underwent ultrasonography to measure lumbar inter-transverse process distances (L1-L5) under four conditions: unloaded standing, unloaded standing for 15 minutes, loaded standing (25kg vest) for 15 minutes, and loaded standing for 30 minutes.
- Measurements were repeated over 1-7 days to assess inter-rater, within-visit, and between-visit reliability using intraclass correlation coefficients (ICCs) and coefficients of variation (CVs).
- A one-way ANOVA analyzed the effect of loading conditions on inter-transverse process distances.
Main Results:
- Ultrasonography demonstrated good to excellent reliability for inter-rater, within-visit, and between-visit measurements (ICCs: 0.81-0.99; CVs: 5.24%-13.0%).
- Loaded standing for 15 and 30 minutes significantly reduced inter-transverse process distances at L2/3, L3/4, and total lumbar distance (p < 0.05).
Conclusions:
- Ultrasonography is a reliable and cost-effective tool for quantifying lumbar spine geometric changes during loaded standing.
- This technique shows potential for assessing spinal compression in response to mechanical load in occupational and clinical environments.
Related Concept Videos
Behavior of Concrete Under Compressive Load
653
Concrete exhibits specific behaviors under different compressive loads. Understanding this is crucial for understanding its structural integrity. When concrete undergoes uniaxial compression, it tends to develop cracks that run parallel to the direction of the force. These parallel cracks stem from localized tensile stresses that occur perpendicular to the compression direction. Additionally, angled cracks may appear due to the formation of shear planes.
As the concrete specimen fractures under...
As the concrete specimen fractures under...
653
Ultrasonography
8.0K
Ultrasonography is an imaging technique that uses high-frequency sound waves to visualize the body's internal structures. It is a non-invasive and safe procedure that does not involve the use of ionizing radiation, making it widely used in various medical fields. Ultrasonography is used to study heart function, blood flow in the neck or extremities, certain conditions such as gallbladder disease, and fetal growth and development.
During an ultrasonography procedure, a handheld device called...
During an ultrasonography procedure, a handheld device called...
8.0K
Reliability and Validity
14.1K
Reliability and validity are two important considerations that must be made with any type of data collection. Reliability refers to the ability to consistently produce a given result. In the context of psychological research, this would mean that any instruments or tools used to collect data do so in consistent, reproducible ways.
14.1K
Imaging Studies II: Ultrasonography
510
IntroductionUltrasonography, or renal ultrasound, is a noninvasive medical imaging technique that uses high-frequency sound waves to visualize the kidneys, ureters, bladder, and surrounding tissues.Indications for Urinary System UltrasonographyUrinary system ultrasonography is indicated in various clinical scenarios, such as:Kidney Stones (Urolithiasis): To detect and monitor the size and presence of kidney or urinary tract stones.Hydronephrosis: To assess the dilation of the renal pelvis and...
510
Ultrasound I: Abdominal Ultrasonography
1.8K
Introduction:
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
1.8K
Distribution Reliability and Automation
520
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...