Assessing Axis-specific Set-up Errors in Rectal Cancer Radiotherapy: A Prospective Cone-beam Computed
Ainain Yousuf Baba1, Abid Ahmad2, Obair Yousuf Baba3
1Department of Physics, University of Kashmir, Srinagar, Jammu and Kashmir, India.
Purpose:
The purpose of the study was to quantify set-up errors and derive optimal clinical target volume to Planning Target Volume (PTV) margins for rectal cancer patients undergoing radiotherapy, while also evaluating the influence of body mass index (BMI) on set-up accuracy.
Materials And Methods:
Data from 41 patients and 1102 daily cone-beam computed tomography (CBCT) scans were analyzed. For each patient and fraction, the mediolateral (X), craniocaudal (Y), and antero-posterior (Z) translational shifts were measured. Population systematic (Σ) and random (σ) errors were calculated from per-patient summary statistics (see Methods), and PTV margins were derived using the van Herk formula (margin = 2.5 Σ +0.7 σ).
Results:
The mean systematic set-up error was small: 0.04 mm (X), 0.57 mm (Y), and 0.13 mm (Z), reflecting high reproducibility of daily image-guided positioning. Using Σ and σ, the derived PTV margins were 7.4 mm (X), 9.1 mm (Y), and 9.7 mm (Z). A moderate positive correlation between BMI and the Z-axis set-up error was observed (r = 0.55, P = 0.002). Overall, 23.1% of fractions required corrections >5 mm, underlining the value of daily CBCT.
Conclusion:
Nonuniform, axis-specific margins are essential to accommodate anatomical and physiological variability in rectal cancer radiotherapy. The use of daily CBCT significantly enhanced set-up precision. Findings align with ICRU 62/83 and QUANTEC recommendations and support individualized planning approaches, especially in diverse patient populations where BMI and pelvic anatomy may affect positioning accuracy.
More Related Videos
05:37Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
15:18Near Infrared Optical Projection Tomography for Assessments of β-cell Mass Distribution in Diabetes Research
Published on: January 12, 2013
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Correlations
Reduced Mass Coordinates: Isolated Two-body Problem
Hypothalamic-Pituitary Axis