Related Experiment Video
Updated: Feb 15, 2026

12:11
Using Optical Tweezers for the Generation of Hybrid Spheroids
Published on: May 30, 2025
1.0K
Flow Plastometry of Microplastics Using Optical Line Tweezers
Jee Won Lee1, Subeen Park1,2, Jin Il Jang1
1Department of Chemistry, Kookmin University, Seoul 02707, Republic of Korea.
ACS Sensors
|February 13, 2026
Summary
This study presents a new system for analyzing microplastics (MPs) in water. The method allows for real-time, simultaneous morphological and chemical characterization of MPs down to 500 nm.
Area of Science:
- Environmental Science
- Analytical Chemistry
- Materials Science
Background:
- Microplastics (MPs) pose risks to ecosystems and human health, with significant presence in aquatic environments.
- MP toxicity is influenced by chemical composition and physical characteristics.
- Current preparation methods can alter MPs and interfere with analysis.
Purpose of the Study:
- To develop advanced analytical methods for microplastic characterization.
- To enable simultaneous morphological and chemical analysis of MPs.
- To facilitate real-time monitoring of MPs in aquatic systems.
Main Methods:
- A novel system using Raman line monitoring and trapping was developed.
- A protocol for optical immobilization enabled Raman signal acquisition from particles as small as 500 nm.
- Simultaneous morphological and chemical analysis was performed in a flow channel.
Main Results:
- The system achieved simultaneous morphological and chemical analysis of MPs.
- The protocol successfully acquired Raman signals from sub-micron particles.
- The developed approach offers a powerful tool for MP analysis.
Conclusions:
- The novel system provides a robust method for real-time microplastic monitoring.
- This technique overcomes limitations of traditional preparation methods.
- It aids in understanding the risks associated with microplastics in aquatic environments.
Related Concept Videos
Gene Flow
38.1K
Gene flow is the transfer of genes among populations, resulting from either the dispersal of gametes or from the migration of individuals.
38.1K
Properties of Enantiomers and Optical Activity
21.9K
It is essential to understand the difference between chiral and achiral interactions and the implications thereof in optical activity and their applications. Just as our feet, which are chiral, interact uniquely with chiral objects, such as a pair of shoes, but identically with achiral socks, enantiomers of a molecule exhibit different properties only when they interact with other chiral media. An example of a significant implication from this facet is the phenomenon known as optical activity,...
21.9K
Flow Cytometry
16.5K
The development of flow cytometry techniques began in 1934 with initial attempts by Andrew Moldavan, a bacteriologist who counted the cells in a flowing capillary system. Moldavan pumped cells through a capillary tube focused under a microscope for visualization. The invention of photometry allowed the measurement of differentially-stained cells, and Louis Kamentsky developed the first multiparameter flow cytometer in 1965 to identify and count the cancer cells in cervical tissue specimens.
In...
In...
16.5K
Flow Sheet
2.9K
Flowsheets are valuable tools in nursing documentation. They enable healthcare professionals to efficiently record and monitor various patient assessments and measurements in a consolidated format.
Here's a closer look at the examples of flowsheets commonly used by nurses:
Graphic Sheet Documentation:
Here's a closer look at the examples of flowsheets commonly used by nurses:
Graphic Sheet Documentation:
2.9K
Flow Table Test
772
The flow table test is an established method used to assess the workability of concrete, particularly useful for evaluating highly flowable concrete mixes. This test employs an apparatus that consists of a wooden board topped with a steel plate, collectively weighing 35 pounds. The board is connected to a base via a hinge and measures 27.6 inches on each side.
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...
772
Irrotational Flow
1.0K
Irrotational flow is characterized by fluid motion where particles do not rotate around their axes, resulting in zero vorticity. For a flow to be irrotational, the curl of the velocity field must be zero. This imposes specific conditions on velocity gradients. For instance, to maintain zero rotation about the z-axis, the gradient condition:
1.0K

