Related Experiment Video
Updated: Feb 15, 2026

Manufacturing Abdominal Aorta Hydrogel Tissue-Mimicking Phantoms for Ultrasound Elastography Validation
Published on: September 19, 2018
Quantification of dual-state 5-ALA-induced PpIX fluorescence: methodology and validation in tissue-mimicking phantoms
Silvere Segaud1, Charlie Budd1, Matthew Elliot1,2
1Research Department of Surgical & Interventional Engineering, School of Biomedical Engineering & Imaging Sciences, King's College London, London SE1 7EH, United Kingdom.
Abstract:
Quantification of protoporphyrin IX (PpIX) fluorescence in human brain tumours has the potential to significantly improve patient outcomes in neuro-oncology, but represents a formidable imaging challenge. Protoporphyrin is a biological molecule which interacts with the tissue micro-environment to form two photochemical states in glioma. Each exhibits markedly different quantum efficiencies, with distinct but overlapping emission spectra that also overlap with tissue autofluorescence. Fluorescence emission is known to be distorted by the intrinsic optical properties of tissue, coupled with marked intra-tumoural heterogeneity as a hallmark of glioma tumours. Existing quantitative fluorescence systems are developed and validated using simplified phantoms that do not simultaneously mimic the complex interactions between fluorophores and tissue optical properties or micro-environment. Consequently, existing systems risk introducing systematic errors into PpIX quantification when used in tissue. In this work, we introduce a novel pipeline for quantification of PpIX in glioma, which robustly differentiates both emission states from background autofluorescence without reliance ona priorispectral information, and accounts for variations in their quantum efficiency. Unmixed PpIX emission forms are then corrected for wavelength-dependent optical distortions and weighted for accurate quantification. Significantly, this pipeline is developed and validated using novel tissue-mimicking phantoms replicating the optical properties of glioma tissues and photochemical variability of PpIX fluorescence in glioma. Our workflow achieves strong correlation with ground-truth PpIX concentrations (R2=0.918±0.002), demonstrating its potential for robust, quantitative PpIX fluorescence imaging in clinical settings.
More Related Videos
Related Concept Videos
Reliability and Validity
Chemotherapy-Induced Nausea and Vomiting: 5-HT3 Receptor Antagonists
5-Number Summary
In a box plot, the minimum and maximum data values represent the lower and upper whiskers in the graph, and the median is designated as the center of the box in the chart. The first quartile and third...
Data Validation
Key parameters for method validation include:
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
Response Surface Methodology
The process of RSM involves several key steps: