Related Experiment Video
Updated: Feb 15, 2026

Measuring Retinal Vessel Diameter from Mouse Fluorescent Angiography Images
Published on: May 19, 2023
Prediction of occluded-side M1 vessel diameter using pre-procedural magnetic resonance angiography
Takaaki Kitano1, Hiroyuki Ikeda1, Hidenobu Hata1
1Department of Neurosurgery, Kurashiki Central Hospital, Kurashiki, Japan.
Purpose:
To determine whether the occluded-side M1 vessel diameter on post-procedural digital subtraction angiography (DSA) can be predicted from that on pre-procedural magnetic resonance angiography (MRA) and its usefulness for aspiration catheter selection.
Methods:
We retrospectively analyzed 41 cases of M1 occlusion undergoing mechanical thrombectomy with successful recanalization and pre- and post-procedural MRA at our institution between January 2020 and December 2024. The relationship between the catheter-to-vessel ratio (CVR), calculated from aspiration catheter's outer diameter and occluded-side M1 vessel diameter on pre-procedural MRA, and first-pass effect was assessed.
Results:
The mean occluded-side M1 vessel diameter was 2.2 ± 0.3 mm on pre-procedural MRA and 2.4 ± 0.4 mm on post-procedural DSA; the latter showed a strong correlation with the former (r = 0.925, p < 0.001), and the regression equation was as follows: occluded-side M1 vessel diameter on post-procedural DSA (mm) = 0.19 + 1.025 × occluded-side M1 vessel diameter on pre-procedural MRA (mm) (R² = 0.856). The occluded-side M1 vessel diameter on post-procedural DSA approximated from the mean occluded-side M1 vessel diameter on pre-procedural MRA was pre-procedural MRA measurement + 0.2 mm. First-pass effect was achieved in 66.7 % of cases with CVR ≥ 0.80 and in 25.0 % of cases with CVR < 0.80 (p = 0.049).
Conclusion:
When treating M1 occlusion, adding 0.2 mm to the occluded-side M1 vessel diameter on pre-procedural MRA measurement allows prediction of the actual M1 vessel diameter. Selecting an aspiration catheter with CVR ≥ 0.80 may help achieve first-pass effect.
More Related Videos
13:56The Use of Magnetic Resonance Spectroscopy as a Tool for the Measurement of Bi-hemispheric Transcranial Electric Stimulation Effects on Primary Motor Cortex Metabolism
Published on: November 19, 2014
11:27Magnetically-Assisted Remote Controlled Microcatheter Tip Deflection under Magnetic Resonance Imaging
Published on: April 4, 2013
Related Concept Videos
Handwashing II: Pre-procedure and Initial Procedure Steps
The hand washing procedure itself includes the following steps. First, cover cuts, if any, on hands with a waterproof dressing. Cuts and abrasions can become contaminated with bacteria hindering the ability to clean the area thoroughly. In addition, repeated hand washing can worsen an injury. The nails must be short and clean, without nail...
Magnetic Resonance Imaging
Cardiac Catheterization I: Pre-Procedure Overview
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Atomic Nuclei: Magnetic Resonance