Automatic field-of-view planning for magnetic resonance shoulder imaging using Deep Learning
Anton Sheahan Quinsten1, Simon Joshua Hornisch2, Marcel Gratz3
1Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, 45147 Essen, Germany.
Introduction:
Accurate prescription of oblique coronal and oblique sagittal field of views (FOV) is essential for diagnostic shoulder MRI. Manual planning is radiographer-dependent, time-consuming, and subject to inter- and intra-operator variability, leading to inconsistent image quality and incomplete coverage. Although deep learning (DL) has advanced automated scan planning in non-oblique planes, oblique shoulder prescriptions remain underexplored; an automated DL approach could standardize FOV prescription, reduce operator dependence, and improve reproducibility and workflow without compromising diagnostic quality.
Methods:
In this retrospective multicenter study, 575 shoulder MRI examinations (2019-2025) from four sites were included. Sites A (n=151) and B (n=220) were used for training; testing was performed on sites C (n=61), and D (n=143). A two-stage pipeline was implemented using five oriented bounding box (OBB) variants of YOLOv11 (n, s, m, l, x): Stage 1 performed slice selection; Stage 2 performed FOV prescription. Performance was evaluated against radiographers' prescriptions using mean absolute slice difference (MASD, slices), intersection over union (IoU), and mean absolute angle difference (MAAD, degrees). Clinical utility was assessed by three raters.
Results:
The YOLOv11-OBB-l model achieved the lowest MASD for Stage 1 (1.016±0.153 slices). For Stage 2, YOLOv11-OBB-x performed best (coronal IoU, 0.847±0.003; sagittal IoU, 0.852±0.007; MAAD, 3.259±0.190°). During testing across each site, MASD ranged from 0.700±0.837 to 1.192±2.550 slices; MAAD from 2.811±2.348 to 4.396±7.158°; coronal IoU from 0.800±0.092 to 0.872±0.065; and sagittal IoU from 0.824±0.111 to 0.887±0.047. Mean clinical utility was 97.2%. Performance was noninferior to interrater variability across all sites and metrics.
Conclusion:
DL-based automated FOV prescription for shoulder MRI achieves performance comparable to radiographers, generalizes across institutions, and demonstrates high clinical utility.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Magnetic Fields
A magnetic field is defined by the force that a charged particle experiences...
Magnetic Field of a Solenoid
Consider a solenoid with 100 turns wrapped around a cylinder of...
Magnetic Field Lines
Magnetic field lines follow several hard-and-fast rules:
Energy In A Magnetic Field
Take an ideal inductor with zero resistance. Although it's practically impossible, assume that the coil's resistance is so small that it is practically negligible. The loss of the field's energy to dissipate thermal energy (or heat) is thus...