Related Experiment Video
Updated: Feb 15, 2026

Author Spotlight: Unveiling Prognostic Indicators in Heart Failure - The Role of Phase Angle and Bioelectrical Impedance Analysis
Published on: June 30, 2023
Functional cognitive screening instruments and their clinical utility with older adults in the emergency department:
Francis S Gomes1, Justin Newton Scanlan2, Anne Cusick2
1Faculty of Medicine and Health, University of Sydney, Susan Wakil Health Building, D18 Western Ave, Camperdown, NSW 2006, Australia; Department of Occupational Therapy, Blacktown Hospital, Western Sydney Local Health District, Sydney, Australia.
Abstract:
Cognitive screening is a vital part of geriatric emergency department (ED) care. Performance-based functional cognitive measures may better identify impairments and predict post-discharge outcomes in daily activities. Currently, there is no evidence base informing the selection of suitable functional cognition instruments for emergency care. We conducted a systematic review to find psychometrically sound clinically useful instruments for assessing functional cognition in older adults in the ED. Six databases were searched to identify performance-based instruments measuring functional cognition and related psychometric studies, using COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN). Studies with a mean age under 65 were excluded. Clinical utility in the ED was evaluated using a newly updated, author-designed, criterion-based consensus matrix. Results were synthesised into a best-evidence summary. We identified 28 instruments and 44 adaptations across 138 studies assessing eight of the nine measurement properties. Construct validity (discriminative and convergent) was most frequently evaluated (87 %). Three instruments met all eight clinical utility criteria; however, none have been tested in ED: the Texas Functional Living Scale (moderate-high sufficient construct validity); the Menu Task (moderate-high sufficient construct validity, low-very low sufficient internal consistency and reliability), and the Pillbox Test (moderate sufficient predictive, high sufficient discriminative, moderate inconsistent convergent validity). Overall, 61 % of psychometric studies were rated as very good methodological quality. Our study is the first to identify existing instruments with established psychometric evidence that also meet clinical utility criteria for use with older adults in the ED. Robust studies are urgently needed to evaluate predictive validity for post-discharge outcomes.
Related Concept Videos
Revisionist Views of Adolescent and Adult Cognition
Cognitive Dissonance
Emerging Adulthood
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...

