Related Experiment Video
Updated: Feb 15, 2026

Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
Robotic-Arm Assisted Multi-Apical View 3-D Fusion of Echocardiography for Enhanced Left Ventricular Assessment Using
Khalid Alquwaynim1, Michelle Noga2, Harald Becher3
1Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada; College of Applied Medical Science, King Saud Bin Abdulaziz University for Health Sciences, Al-Ahsa, Saudi Arabia.
Objective:
Accurate assessment of left ventricular (LV) function using three-dimensional echocardiography (3-DE) remains limited by suboptimal image quality and restricted field of view. This study proposes a robotic-arm-assisted acquisition protocol combined with a wavelet-based multi-apical view fusion approach to enhance LV image quality in 3-DE.
Methods:
Volunteer scans were acquired using a UR10e robotic arm integrated with a Philips EPIQ 7C ultrasound system to ensure consistent multi-apical 3-DE acquisition. Echocardiographic volumes were converted to NRRD format using 3-D Slicer for visualization and verification of spatial and temporal alignment. Two-view and three-view apical datasets were fused using a wavelet-based approach. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were computed from matched 2-D slices in the end-diastolic phase, and qualitative image assessment was conducted by expert raters using blinded scoring of image clarity, myocardial border continuity and diagnostic confidence.
Results:
Wavelet-based fusion significantly improved image quality compared to single-view 3-DE, with increased SNR (9.36 ± 5.03 vs. 7.09 ± 4.44, p < 0.0001) and CNR (1.68 ± 0.54 vs. 1.49 ± 0.57, p = 0.0020). Three-view fusion provided additional quantitative improvement over 2-view fusion. Inter-rater agreement on visual assessment confirmed that fused images were consistently rated as equal or superior in quality, with substantial agreement across all scoring categories.
Conclusion:
Wavelet-based fusion of multi-apical 3-DE images acquired with robotic arm assistance significantly enhances image quality for LV assessment, improving both quantitative metrics and visual interpretability, practically with the 3-view fusion. The use of the robotic arm played a key role in ensuring standardized and reproducible probe positioning, which is essential for successful image alignment and fusion. This approach demonstrates the potential to improve the reliability and diagnostic value of 3-DE, and future work should explore incorporating additional views and deep learning methods to further advance robotic-assisted cardiac imaging.
More Related Videos
06:34Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
Published on: October 28, 2020
08:19Transthoracic Echocardiography to Assess Post-Resuscitation Left Ventricular Dysfunction After Acute Myocardial Infarction and Cardiac Arrest in Pigs
Published on: July 12, 2022
Related Concept Videos
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Nuclear Fusion
A helium nucleus has a mass that is 0.7% less than that of four hydrogen nuclei; this lost mass is converted into energy during the fusion. This reaction produces about...
Self-Evaluation: Self-Enhancement and Self-Verification
Muscles that Move the Arm
The pectoralis major has two origins. Its clavicular head originates on the medial half of the clavicle. In contrast, the sternocostal head originates on the costal cartilages of ribs 1-6, the sternum, and the aponeurosis of the external oblique of the...
Econometric Views (EViews)