A modified broad beam model for uniformly scanned carbon ion therapy accounting for field inhomogeneities
1Department of Medical Management, Chinese Academy of Science Heavy Ion Medicine (CASHIM) Co. Ltd., Beijing, China. yzxia@cashim.cn.
Abstract:
The purpose was to perform beam modeling and plan verification for uniform scanned (US) carbon ion therapy delivered by Heavy Ion Medical Machine (HIMM). As the field inhomogeneity is larger than the commonly accepted 3% gamma pass rate criteria, a simple flat broad beam model is no longer accurate. A modified broad beam model accounting for field inhomogeneity was proposed and validated. The commissioning process for automatic beam modeling was described. Characteristic lateral dose distributions were collected at different depths for each field combination. The field inhomogeneities were modeled as two-dimensional interpolations of the lateral dose data. Dose calculation was based on ray-tracing combined with an asymmetric double-sigmoid function describing the dose at field edge. Two types of plan verifications on three US nozzles were carried out: 1) without range compensators 2) with range compensators. The distance-to-agreement at distal fall-off was within 1 mm. The absolute dose calibration was within 1.9% and the mean value was 0.6 (±0.5%). The verification plans satisfied 95% pass rate based on 3mm/3% gamma analysis for all three nozzles. Comparison with literature suggested a clinical factor of 1.33. The modified broad beam model satisfied the gamma analysis requirement and could be used for commissioning carbon US beams.
More Related Videos
11:03Nanoscale Characterization of Liquid-Solid Interfaces by Coupling Cryo-Focused Ion Beam Milling with Scanning Electron Microscopy and Spectroscopy
Published on: July 14, 2022
10:58Focused Ion Beam Fabrication of LiPON-based Solid-state Lithium-ion Nanobatteries for In Situ Testing
Published on: March 7, 2018
Related Concept Videos
Electric Field of a Non Uniformly Charged Sphere
Consider a non-uniformly charged sphere, for which the density of charge depends only on the distance from a point in space and not on the direction. Such a sphere has a spherically symmetrical charge distribution. Here, the electric...
Electric Potential Energy in a Uniform Electric Field
The Carbon Cycle
Modeling in Therapy
Participant Modeling
Participant modeling involves therapists demonstrating calm and effective behaviors in...
Uniform Distribution
Two essential properties of this distribution are
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...