U-Net and YOLOv8 Artificial Intelligence Models for Automated Recognition of Internal Jugular Veins and Radial
Yunxin Gu1, Gege Tang1, Lan Gao1
1Department of Ultrasound Medicine, the Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, China.
Objectives:
This study compares the U-Net and You Only Look Once version 8 (YOLOv8) models for identifying internal jugular veins (IJVs) and radial arteries (RAs) in longitudinal and/or transversal ultrasound views, evaluating their vascular recognition capabilities for artificial intelligence-guided cannulation systems under point-of-care ultrasound (POCUS) visualization.
Design:
A retrospective study.
Setting:
Six teaching hospitals.
Participants:
Data from 1,122 ultrasound images (612 IJVs, 510 RAs) between January and December 2024.
Interventions:
No intervention.
Measurements And Main Results:
U-Net was employed for pixelwise segmentation with a combined dice-cross-entropy loss, while YOLOv8s-seg incorporated attention mechanisms for object detection. Model performance was evaluated using precision, recall, F1-score, mean average precision at intersection over union (IoU) threshold 0.5 (mAP@0.5), IoU, Dice coefficient, and inference time metrics. YOLOv8 demonstrated superior performance with a precision of 0.996, recall of 1.00, mAP@0.5 of 0.995, IoU of 0.739, Dice coefficient of 0.834, and inference time of 26.3 ms, outperforming U-Net, which achieved a precision of 0.988, recall of 0.998, mAP@0.5 of 0.993, IoU of 0.719, Dice coefficient of 0.816, and inference time of 38.9 ms. In the validation set, YOLOv8 exhibited higher accuracy across all categories, with values of 0.96 for V-S, 0.90 for V-L, 0.89 for A-S, and 0.86 for A-L, compared with U-Net's respective accuracies of 0.81, 0.88, 0.87, and 0.82.
Conclusion:
YOLOv8 outperformed U-Net in accuracy, precision, and speed, proving more suitable for real-time vascular localization in clinical settings. These findings provide critical algorithmic foundations for developing automated vascular puncture navigation platforms in the future.
Related Concept Videos
Intelligence
Measures of Intelligence
Validity refers to how well a test measures what it claims to measure. An intelligence test should accurately assess intelligence rather than another characteristic, like anxiety. Criterion validity is one way to evaluate this;...
Multiple Intelligences Theory
Cattell's Theory of Intelligence
Fluid intelligence involves the capacity to solve new problems and adapt to unfamiliar situations. It's the type of intelligence individuals use when they encounter a novel problem or puzzle that requires innovative thinking. For instance, figuring out how to operate a new gadget relies heavily on...
Triarchic Theory of Intelligence
Biological Influences on Intelligence