Optical Coherence Tomography Radiomics and Machine Learning Enable Accurate Detection of Forme Fruste Keratoconus
Shenglong Luo1, Xuefei Li1, Kuangching Lin1
1From the National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital (S.L., X.L., K.L., F.B., S.C., F.L., J.W.), Wenzhou Medical University, Wenzhou, Zhejiang Province, China; National Clinical Research Center for Ocular Diseases, Eye Hospital (S.L., X.L., K.L., F.B., S.C., F.L., J.W.), Wenzhou Medical University, Wenzhou, Zhejiang Province, China; State Key Laboratory of Eye Health, Eye Hospital (S.L., X.L., K.L., F.B., S.C., F.L., J.W.), Wenzhou Medical University, Wenzhou, Zhejiang Province, China.
Purpose:
To evaluate the diagnostic performance of a radiomics-based machine learning approach applied to corneal optical coherence tomography (OCT) images for detecting forme fruste keratoconus (FFKC).
Design:
Evaluation of machine learning diagnostic algorithms.
Methods:
OCT images from 307 eyes (234 normal, 73 FFKC) were acquired along eight meridians (M1-M8). All images underwent preprocessing before texture-based radiomics feature extraction. Three machine learning classifiers-Random Forest, C5.0, and XGBoost-were trained using a feature subset selected by recursive feature elimination (RFE). Model performance was evaluated using the area under the receiver operating characteristic curve (AUC), sensitivity, specificity, and accuracy.
Results:
A total of 3752 features were extracted per eye, of which 41 were selected for model training. All three models demonstrated strong diagnostic performance in the test set (AUCs > 0.92), with no significant differences between models (P > .05). The XGBoost model achieved the highest performance (AUC = 0.93, 95% CI: 0.829-1.0, sensitivity 0.857, specificity = 0.978, accuracy = 0.950). Among the top 10 XGBoost features ranked by importance, a preferred meridional distribution was observed, with most features concentrated along M1 to M3, corresponding to the inferotemporal corneal region.
Conclusion:
Radiomics analysis of corneal OCT images combined with machine learning enables accurate FFKC detection using a single imaging device, providing diagnostic information beyond conventional morphological assessment and suggesting a potential imaging biomarker for early keratoconus screening.