Source control with masks and respirators in hospitals: exhalation aerosol shedding, jet suppression, and near-/far-field persistence
Related Experiment Video
Updated: Feb 18, 2026

Safety Precautions and Operating Procedures in an ABSL-4 Laboratory: 3. Aerobiology
Published on: October 3, 2016
Weihua Yang1, Warren R Myers2, Kenneth J Ryan3
1School of Safety Engineering, China University of Mining and Technology, Xuzhou, Jiangsu, China; Department of Industrial and Management Systems Engineering, Statler College of Engineering and Mineral Resources, West Virginia University, Morgantown, WV, USA.
Background:
Infectious exhalation aerosol source control using masks and respirators in hospitals depends on the aerosol shedding and its dispersion.
Methods:
In a simulation study with a headform, we used a leakage testing system for total outward leakage (TOL) and count median diameter (CMD) and a separate hood for horizontal exhalation-jet velocity at 1, 2, and 3 ft (0.30, 0.61, 0.91 m). Neutralised NaCl aerosols were generated to mimic human exhalation shedding. Five devices for source control - surgical mask (SM), non-valved N95 filtering facepiece respirator (N95 FFR), valved N95 (FFRV), elastomeric half-mask respirator (EHMR), and EHMR with an SM overlay (EHMRSM) - were tested under three faceseal conditions (0%, 50%, and 100%) and three flow rates (17, 28, 39 L min-1). We derived a near-field (NF) emission index and a far-field (FF) persistence index.
Results:
Device type significantly affected TOL and CMD (P < 0.01). The N95 FFR minimised TOL (≈5-9%) and eliminated horizontal jets, yielding near-zero NF and the lowest FF. The EHMR had the highest TOL (≈82-88%) and persistent jets, producing the largest NF and FF; FFRV was intermediate. The SM and EHMRSM collapsed jets (NF≈0) but retained moderate to high TOL, sustaining elevated FF. Leaked particles were predominantly submicron (CMD ≈ 0.42-0.61 μm).
Conclusions:
Gravitational loss (≈0.02-0.05 h-1) is negligible compared with clinical ventilation to clean leaked aerosols, yielding orders of magnitude longer clearance times, so settling alone cannot deliver timely clearance. In practice, low-leakage devices - preferably non-valved N95s - should be paired with adequate air-change rates.
Related Concept Videos
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
PPE Use in Healthcare Settings II: Doffing
Personal Protective Equipment
Transmission-based Precautions I: Contact, Enteric, and Droplets
Contact Precautions:
Contact precautions are the measures taken to prevent the transmission of infectious agents, especially epidemiologically important microorganisms such as MRSA or influenza, primarily transmitted through direct or indirect contact with an...