Few-Shot Personalized Blood Pressure Estimation from Photoplethysmography and Physiological Priors via Low-Rank
Abstract:
Noninvasive continuous blood pressure (BP) monitoring has become a critical requirement for effective health management in the general population. To address the challenge of accurate few-shot personalized BP estimation, a photoplethysmography (PPG)-based framework built on the unified multi-task time series model with a Transformer backbone is proposed. The framework comprises population-level pretraining and personalized fine tuning with a pulse pressure segmented penalty (PPSP) loss. The PPSP couples systolic BP (SBP) and diastolic BP (DBP) outputs by penalizing pulse pressure values outside clinically accepted ranges, which enforces physiological consistency. In addition, a sampling-rate-robust low-rank adaptation (SRR-LoRA) is introduced to improve estimation accuracy when low-frequency PPG signals are employed. After rate alignment, SRR-LoRA prioritizes measurements over interpolated points, suppresses interpolation noise, and preserves cross-device generalization. Model performance was evaluated on the UCI cuffless BP estimation dataset, the University of Queensland vital signs dataset, and the CAS-BP dataset. 113,812 samples from 2,405 subjects were used for pretraining, and data from 316 subjects (each with 50 samples) were included for few-shot fine tuning. The proposed method achieved mean absolute errors of 1.52/1.07 mmHg for SBP/DBP. These results fulfill the Association for the Advancement of Medical Instrumentation BP standard and correspond to Grade A performance according to the British Hypertension Society standard and IEEE 1708 standard, which demonstrates the framework's potential for practical personalized wearable BP monitoring.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...