Integrated pulmonary index (IPI)-guided ventilation management during "tubeless" video-assisted thoracoscopic surgery
Donglai Yan1,2, Yu Bai1,2, Yihua Li1,2
1Department of Anesthesia, Tianjin Medical University General Hospital, Tianjin, China.
Background:
"Tubeless" anesthesia for video-assisted thoracoscopic surgery (VATS) maintains spontaneous ventilation but complicates respiratory monitoring. The integrated pulmonary index (IPI) is a non-invasive tool that assesses respiratory status by integrating four real-time parameters [EtCO2, respiratory rate (RR), heart rate (HR), and SpO2] into a single score ranging from 1 to 10.
Case Presentation:
We present a 42-years-old female who underwent right middle lobectomy under tubeless anesthesia with continuous IPI monitoring. Anesthesia was maintained via laryngeal mask airway with spontaneous ventilation, supplemented by total intravenous anesthesia and paravertebral blockade. The IPI system facilitated tiered respiratory management: IPI ≤ 6 signaled acute respiratory events, while IPI ≤ 4 necessitated immediate assisted ventilation intervention. Real-time IPI tracking ensured respiratory stability (target range 8-10, EtCO2 35-45 mmHg) while promptly identifying deterioration. Postoperative arterial blood gases (PaCO2 42 mmHg, pH 7.33) validated optimal ventilation management.
Conclusion:
This case demonstrates IPI's efficacy in detecting early ventilatory compromise during tubeless VATS, enabling proactive intervention without compromising surgical advantages. Further refinement of IPI thresholds may enhance perioperative safety in spontaneous ventilation anesthesia.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...