Background:
The permeability of surgical scrubs affects the bacterial load in the operating room (OR) air. Bacterial load can be measured by counting fluorescent bioparticles per unit of air. This study aimed to compare fluorescent bioparticle sized ≥3 μm per 50 dm3 of OR air (FBP) in air during primary arthroplasty surgeries using two different staff clothing systems.
Methods:
The average FBP for 37 consecutive arthroplasty surgeries using reusable scrubs was compared with 37 surgery type-matched arthroplasties using single-use scrubs. An analysis of covariance (ANCOVA) was conducted to analyse the effects of surgery duration on log10-transformed FBP while controlling for the number of staff members present and surgery duration.
Findings:
Mean FBP levels were 101 (95% confidence interval [CI]: 96-107) for the reusable scrubs and 18 (95% CI:16-20) for the single-use scrubs. In the ANCOVA, clothing type was strongly associated with log10-transformed FBP, accounting for 86% of the partial variance (η2 = 0.86). In contrast, neither the number of staff nor surgery duration had a significant effect on FBP.
Conclusion:
Clothing system permeability to bioparticles is one key factor in achieving air with low levels of bioparticles in OR air. Measuring FBP in real time during arthroplasty surgery is a new possibility for studying the effect of distinct OR-related factors on air bacterial load.
Related Concept Videos
PPE Use in Healthcare Settings II: Doffing
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Personal Protective Equipment
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
PPE Use in Healthcare Settings I: Donning