Related Experiment Video
Updated: May 3, 2026

Implementation of a Real-Time Psychosis Risk Detection and Alerting System Based on Electronic Health Records using CogStack
Published on: May 15, 2020
Independent external validation of the LIFE-HF clinical prediction model using the GUIDE-IT trial
Ricky D Turgeon1,2, Nathaniel M Hawkins2, Mohsen Sadatsafavi1
1Collaboration for Outcomes Research and Evaluation, Faculty of Pharmaceutical Sciences, University of British Columbia, Room 5523-2405 Wesbrook Mall, Vancouver, British Columbia, Canada V6T 1Z3.
Introduction:
Accurate prognostication is central to decision-making in heart failure (HF). The recently-developed LIFE-HF models offer promise, but their performance has not been independently and externally validated. The aim of this study was to assess the external validity of the LIFE-HF models in a contemporary North American population.
Methods:
We externally validated the LIFE-HF models for 1-year all-cause death and the composite of death or HF hospitalization using patient-level data from the GUIDE-IT trial. All LIFE-HF predictors were available; missing data were handled using multiple imputation. Predicted risks were calculated using original LIFE-HF model equations. We assessed model discrimination using time-dependent area under the receiver operating characteristic curve (AUROC), calibration [observed-to-expected (O/E) ratios, calibration slopes and curves], overall prediction error, and net benefit using decision curve analysis.
Results:
The validation cohort included 801 participants (median age 64 years, 69% male). The mortality model demonstrated good discrimination [AUROC 0.77, 95% confidence interval (CI): 0.72-0.82], but underprediction (O/E 1.28, 95% CI: 1.01-1.54) and underfitting (calibration slope 1.58, 95% CI: 1.20-1.95). The composite model showed moderate discrimination (AUROC 0.69, 95% CI: 0.64-0.73), underprediction (O/E 1.40, 95% CI: 1.25-1.54), and overfitting (calibration slope 0.82, 95% CI: 0.63-1.00). Decision curve analysis showed net clinical benefit for the mortality model, but not the composite model, over a broad range of risk thresholds.
Conclusion:
In a contemporary, high-risk North American HF with reduced ejection fraction cohort, the LIFE-HF models showed good discrimination but systematically underpredicted 1-year risk. The mortality model may support risk-informed decision-making, whereas the composite model requires further validation.
Related Concept Videos
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
Clinical Trials
There are four phases in a clinical trial. A phase one...
Clinical Trials: Overview
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Bioavailability Study Design: Healthy Subjects Versus Patients