Related Experiment Video
Updated: May 1, 2026

Experimental Protocol of a Three-minute, All-out Arm Crank Exercise Test in Spinal-cord Injured and Able-bodied Individuals
Published on: June 8, 2017
Test-Retest Reliability of Single-Arm Closed Kinetic Chain Upper Extremity Stability Test
Andy Waldhelm1,2, Mareli Klopper3, Matthew Paul Gonzalez4
1School of Rehabilitation, South College, 400 Goody Lane, Knoxville, TN 37922, USA.
None:
Background: The original Closed Kinetic Chain Upper Extremity Stability Test (CKCUEST) is a simple assessment tool but does not account for individual differences in hand starting position and fails to provide information on limb asymmetries. The purpose of the study is to evaluate the test-retest reliability of a new single-arm CKCUEST as well as the reliability of the limb symmetry index (LSI). This version normalizes the test based on the participant's arm length and allows for the assessment of limb symmetry since it is performed one arm at a time. Methods: Twelve healthy young adults provided both verbal and written consent to participate. Participants were excluded if they had sustained an injury in the past three months requiring medical attention and/or resulting in decreased activity for more than three days. Testing was conducted in the push-up position with participants' thumbs placed parallel and at a distance equal to the length of their dominant arm (measured from the acromion to the tip of the middle finger), and feet positioned shoulder-width apart. Participants were instructed to keep the testing hand stable on the floor while the opposite hand reached across the body to touch the stationary hand and then return to the starting position marked with athletic tape. The goal was to complete as many touches as possible in 15 s, with each touch counted only if the participant touched the stationary hand, returned to the starting position, and maintained the shoulder-width stance. The average number of touches from the three trials was used for analysis. Intraclass Correlation Coefficients (ICC(3,1)) were computed to determine test-retest reliability. Results: Test-retest reliability of the single-arm CKCUEST individual tests was good to excellent. The ICC(3,1) was 0.88 (95% CI: 0.74-0.95) for all tests, 0.89 (95% CI: 0.66-0.96) for the dominant arm, and 0.93 (95% CI: 0.78-0.98) for the non-dominant arm. In contrast, the reliability of the Limb Symmetry Index (LSI) was questionable, showing substantial variability with an ICC(3,1) of 0.53 (95% CI: -0.03-0.83) between Day 1 and Day 2, despite similar mean values (Day 1: 93.6 ± 8.46; Day 2: 94.8 ± 5.77). The Kappa coefficient suggested a substantial level of agreement for the direction of the asymmetry (preferred limb) (Kappa coefficient = 0.62). Conclusions: The new single-arm CKCUEST, which personalizes the hand starting position and measures limb symmetry, demonstrates high reliability among healthy young adults.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
07:52Evaluating Postural Control and Lower-extremity Muscle Activation in Individuals with Chronic Ankle Instability
Published on: September 18, 2020
Related Concept Videos
Static Equilibrium - II
Machines: Problem Solving I
The toggle clamp system is a machine structure consisting of movable, pin-connected multi-force members that form a stabilized system to transmit forces. The...
Stability of Equilibrium Configuration
A stable equilibrium occurs when a system tends to return to its original position when given a small displacement, and the potential energy is at its minimum. An example of a stable equilibrium is when a cantilever beam is fixed at one end and a weight is attached to the other end. If the weight...
Stability of structures
Pole and System Stability
Simple poles are unique roots of the denominator polynomial. Each simple pole corresponds to a distinct solution to the system's characteristic equation, typically resulting in exponential decay terms in the system's...
Stability
The stability of an LTI system is determined by the roots of its characteristic equation, known as poles. A system is stable if it produces a bounded...