Related Experiment Video
Updated: May 2, 2026

Resonance Fluorescence of an InGaAs Quantum Dot in a Planar Cavity Using Orthogonal Excitation and Detection
Published on: October 13, 2017
Amplifying Circularly Polarized Light Emission and Detection via Nonerosive Hetero-Ligand Complexation Doping in
Bo Yang1,2,3, Suqiong Yan3, Haichuan Qin2
1Key Laboratory of Energy Chemical Industry Digitization and Low-Carbon Manufacturing of Sichuan Provincial Education Department, Sichuan University of Arts and Science, Dazhou 635000, P. R. China.
Abstract:
Nonerosive lattice doping of chiral self-assembly is advantageous for applications in polarized optoelectronics, as it evades the packing of molecular rearrangements that preserve the optical activity of microcrystals. However, present chiral microcrystals of phosphine-involved clusters often suffer from low quantum yields and dissymmetry factors (glum) of circularly polarized phosphorescence (CPP), due to limited control over the electromagnetic dipole moment and assembly compatibility of the host and guest. Here, we use chiral diphosphines and trace triphenylphosphines (TPPs) to govern the coordination and nonerosive doping of the binuclear Cu(I) clusters, as demonstrated with a family of heterogeneously doped hexagonal microcrystals based on (R)/(S)-Cu. Green CPP employing one of these pure (R)/(S)-Cu achieves a PLQY and glum of 5.7% and ±0.006, respectively, while the isostructural (R)/(S)-Ag emits similar CPP with lower PLQY (3.5%) and glum values (±0.004), which is caused by excited state deformation and weaker H-bonding. By further preparing crystals through trace doping of TPPs, all crystals feature the same hexagonal morphologies, but phosphorescence enhancement from trace heteroligand-chelated complexes and electronic configurations enables extra triplet populations and decay channels. Thus, the crystals show enhanced PLQYs for red-shifted CPP, as well as better CPL detection (gres = 0.17) and scintillator imaging abilities.
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors

