Related Experiment Video
Updated: Feb 22, 2026

Novel Diagnostics in Revision Arthroplasty: Implant Sonication and Multiplex Polymerase Chain Reaction
Published on: December 3, 2017
The long-term revision risk of RSA-tested and non-RSA-tested TKA implants in The Netherlands: a Dutch arthroplasty
Thies J N Van der Lelij1, Bart G Pijls2, Bart L Kaptein3
1Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands. T.J.N.van_der_lelij@lumc.nl.
Background And Purpose:
Radiostereometric analysis (RSA) of total knee arthroplasty (TKA) is used as an early safeguard during the phased evidence-based introduction of new implants. The goal of our study was to compare the long-term revision risk between RSA-tested implants and non-RSA-tested implants in the Netherlands using patient-level data.
Methods:
All primary TKAs between 2007 and 2016 from the Dutch Arthroplasty Register were included, and procedures with an RSA-tested implant were identified. Both all-cause major revision risk and revision risk because of loosening were calculated at 5 and 10 years postoperatively using Kaplan-Meier analyses. Sensitivity analyses were performed with stricter definitions of implant characteristics to classify procedures as RSA-tested, to avoid camouflage of different subdesigns within the same brand implant portfolio.
Results:
83,638 RSA-tested and 104,105 non-RSA-tested TKAs were included. Cumulative all-cause major revision percentages for the RSA-tested group at 5 and 10 years were 2.2% (95% confidence interval [CI] 2.1-2.3) and 3.6% (CI 3.4-3.7), respectively, compared with 2.5% (CI 2.4-2.6) and 3.3% (CI 3.2-3.4) for the non-RSA-tested group. RSA-tested TKAs showed higher 10-year revision risks because of loosening than non-RSA-tested procedures (1.8%, CI 1.7-1.9 vs 1.4%, CI 1.3-1.4, respectively). Comparable results were found after stratification by various patient characteristics and with stricter classification approaches.
Conclusion:
Regarding all-cause revision risk, RSA-tested TKAs had a slightly lower risk at 5 years. However, at 10 years the RSA-tested TKAs had a higher all-cause revision risk and higher revision risk because of loosening compared with the non-RSA-tested TKAs.