Related Experiment Video
Updated: Feb 22, 2026

09:32
Resolving Water, Proteins, and Lipids from In Vivo Confocal Raman Spectra of Stratum Corneum through a Chemometric Approach
Published on: September 26, 2019
7.7K
Differentiation between mycosis fungoides, parapsoriasis, and distinct types of eczema using ATR-FTIR Spectroscopy
Charlotte Delrue1, Zen Van Gaever2, Shana De Ruyck3
1Department of Nephrology, Ghent University Hospital, Ghent, Belgium.
The Journal of Investigative Dermatology
|February 20, 2026
Abstract
No abstract available in PubMed .
More Related Videos
Related Concept Videos
IR Frequency Region: Fingerprint Region
2.0K
IR spectra are divided into two main regions: the diagnostic region and the fingerprint region. The diagnostic region of the spectrum lies above 1500 cm−1. The absorptions resulting from single-bond vibrations of the N–H, C–H, and O–H stretch at higher wavenumbers and appear on the left side of the spectrum. The stretching absorptions of the C≡C and C≡N occur between 2100–2300 cm−1. In contrast, those arising from stretching absorptions of the...
2.0K
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
1.3K
Attenuated total reflectance (ATR) infrared spectroscopy is a powerful analytical technique used to study the composition of materials. It is widely employed in chemistry, materials science, forensic science, and other fields where sample characterization is required. ATR has several advantages over traditional transmission IR spectroscopy, including the requirement of little to no sample preparation and the ability to analyze a wide range of samples.
The ATR process begins by directing a beam...
The ATR process begins by directing a beam...
1.3K
IR Spectrometers
2.7K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
2.7K
UV–Vis Spectroscopy: Woodward–Fieser Rules
28.7K
UV–Visible absorption spectra of conjugated dienes arise from the lowest energy π → π* transitions. The light-absorbing part of the molecule is called the chromophore, and the substituents directly attached to the chromophore are called auxochromes. A strong correlation exists between the absorption maxima, λmax, and the structure of a conjugated π system. The Woodward–Fieser rules predict the value of λmax for a given structure by adding the...
28.7K

