Egg-level temperature monitoring and CFD-guided structural optimization improve thermal uniformity and hatch
Mingyang Li1, Zefeng Shi1, Zongchun Bai1
1Institute of Agricultural Facilities and Equipment, Jiangsu Academy of Agricultural Sciences, Nanjing 210014, China; Key Laboratory of Protected Agriculture Engineering in the Middle and Lower Reaches of Yangtze River, Ministry of Agriculture and Rural Affairs, Nanjing 210014, China.
Abstract:
Temperature uniformity inside commercial tunnel incubators is critical for hatchability and chick quality, but quantitative field data and validated engineering solutions remain limited. This study combined in situ EST measurements, hatch performance evaluation and computational fluid dynamics (CFD) modeling to characterize and improve the thermal environment in a single-stage tunnel incubator. In one tunnel incubator (capacity 90,720 eggs; operated under standard single-stage conditions), eggshell temperature (EST) was monitored at 15 locations (5 trolleys × 3 vertical tiers; 1-min logging for 12 h on embryonic day 1) during half-capacity (37,800 eggs) loading. Hatchability, hatch time, and chick weight uniformity were evaluated by tier using 5 replicate hatches, with trolley-within-tier as the experimental unit. A porous-medium CFD model was validated against the 15-point EST dataset and used to test transverse trolley orientation and a perforated flow-straightening plate. Under baseline conditions, maximum intra-trolley temperature differences reached 0.84°C and trolley-level non-uniformity indices approached 0.62±0.33%. Eggs on the middle tier, which experienced warmer and more stable temperatures, showed higher hatchability (p < 0.05), earlier mean hatch time (p < 0.05) and greater chick weight uniformity (p < 0.05) than upper and lower tiers. The CFD model reproduced measured temperatures with a maximum absolute deviation of 0.35°C and predicted that transverse trolley orientation could reduce non-uniformity indices to 0.29±0.12%, while the perforated plate reduced them to 0.38±0.14%. Field implementation of transverse trolley orientation confirmed improved temperature uniformity. These findings demonstrate that egg-level monitoring combined with CFD-guided structural optimization can substantially improve the thermal environment in commercial tunnel incubators and support more uniform broiler chick production.
Related Concept Videos
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55...
Thermal Stress
Temperature and Thermal Equilibrium
The concept of temperature has evolved from the common concepts of hot and cold. The scientific definition of temperature explains more than just our sense of hot and cold. Temperature is operationally defined as the quantity measured with a thermometer. Furthermore, temperature is...
Physical Methods for Controlling Microbial Growth: Temperature
Mechanisms of Heat Transfer II
Mechanism of heat transfer