Proof-of-Concept Automated Framework for Intraoperative Transesophageal Echocardiography: View Classification and
Trevor Chan1, Shir Goldfinger2, Rachel Hannah Grasfield3
1Department of Radiology, University of Pennsylvania, Philadelphia; Department of Bioengineering, University of Pennsylvania, Philadelphia.
Objective:
To develop a proof-of-concept automated framework for integrated intraoperative transesophageal echocardiography (TEE) interpretation, encompassing view classification, left ventricular ejection fraction (LVEF) and right ventricular systolic function (RVSF) assessment, and tricuspid regurgitation (TR) grading.
Design:
This cross-sectional study used TEE video clips and reports from patients undergoing cardiac surgery from 2018 to 2023.
Setting:
Two hospitals within the University of Pennsylvania Healthcare System.
Participants:
Study participants were ≥18 years of age and undergoing any cardiac surgery in which an intraoperative TEE was performed. We used 6,900 intraoperative TEE studies from 6,016 unique patients.
Interventions:
Receipt of intraoperative TEE examination during cardiac surgery.
Measurements And Main Results:
The view classification model was trained on TEE clips from 1,432 studies, and the diagnostic model was trained on clips from 6,400 studies, for a total of more than 700,000 individual TEE clips for training. Performance was evaluated on 945 test clips from 8 studies for view classification and 500 studies for diagnostic prediction. No external testing was performed. The view classifier achieved 86% accuracy compared to the expert agreement top-1 weighted accuracy of 74%. The diagnostic model differentiated LVEF >55% versus ≤55% (area under the receiver operating characteristic curve [AUROC] = 0.86) and LVEF >30% versus ≤30% (AUROC = 0.95). Continuous LVEF prediction was assessed (Pearson r = 0.79, mean absolute error = 7.8). The model differentiated normal versus abnormal RVSF (AUROC = 0.82) and differentiated less-than-moderate versus moderate-or-greater right ventricular dysfunction (AUROC = 0.92). Additionally, the model differentiated no TR versus any TR (AUROC = 0.69) and differentiated less-than-moderate versus moderate-or-greater TR (AUROC = 0.79).
Conclusions:
This proof-of-concept automated approach showed encouraging results for view classification and quantification tasks, suggesting potential for further development toward intraoperative utility.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...