Related Experiment Video
Updated: Feb 24, 2026

Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
Safety, cost and environmental impact of reprocessing low and moderate risk single-use medical devices: a systematic
Niamh McGrath1, Catherine Waldron1, Ailish Farragher1
1Evidence Centre, Health Information and Evidence Directorate, Health Research Board, Dublin, Ireland.
Objectives:
Estimate the safety, financial and environmental impacts of reprocessing low and moderate risk single-use medical devices (SuMDs).
Methods:
Systematic review (PROSPERO ID: CRD42022365642) of primary studies of patients receiving reprocessed low and moderate risk SuMDs (non-critical and semi-critical medical devices a and b) versus first use of otherwise identical SuMDs. Items were sourced via database and supplemental searching. Results were reported by device risk class, included studies were quality appraised, and primary outcomes: direct patient safety; direct and indirect financial costs; environmental impacts, were Grade of Recommendation, Assessment, Development and Evaluation (GRADE) assessed following narrative synthesis.
Results:
Ten studies examined 10 devices across three categories of risk class I devices: external fixator devices (n=3 studies), compression sleeves (n=2), and pulse oximeters (n=1) and three categories of risk class II devices: ophthalmic devices (n=1), surgical instruments for grasping and cutting (n=1) and endoscopic and laparoscopic devices (n=5 studies, 5 devices). There were no significant differences in the odds of primary safety outcomes across the two device types contributing data. The only study contributing primary financial impact data reported no statistically significant difference in savings for new versus reprocessed devices (p=0.340). Reprocessing reduced global warming (n=2 studies) and increased human health impacts (n=1) across the four device types contributing data. The certainty of safety and cost evidence was very low.
Conclusions:
Safety monitoring systems where SuMD reprocessing is permitted are required. Reprocessing costs should be estimated using appropriate methodologies and research is needed to ensure that life cycle assessment study designs can be better utilised to inform decision-making.
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...