Related Experiment Video
Updated: Feb 24, 2026

18F-Labeling of Radiotracers Functionalized with a Silicon Fluoride Acceptor SiFA for Positron Emission Tomography
Published on: January 11, 2020
Evaluating [18F]-DCFPyL for Detecting Prostate Cancer Recurrence: A Cost-Consequence Comparison with Alternative PET
Tiago Matos1, Mrunmayee Godbole2, Rithvik Badinedi3
1Alira Health, Global Health Economics, 4057 Basel, Switzerland; tiagofvmatos@gmail.com.
None:
Introduction: [18F]-DCFPyL (Piflufolastat [18F]) is a prostate-specific membrane antigen (PSMA)-targeted position emission tomography (PET) radiotracer for detecting the biochemical recurrence (BCR) of prostate cancer (PCa). This study evaluates its economic impact compared with [68Ga]-PSMA-11, [18F]-FCH, and [18F]-PSMA-1007 from the Spanish National Healthcare System's perspective. Methods: A cost-consequence model, over a 5-year time horizon, simulated the diagnostic and treatment pathway based on radiotracer-specific accuracy and disease localization. Treatment options included a radical prostatectomy, radiation therapy, androgen deprivation therapy (ADT), and radiation therapy + ADT. Costs were calculated for true/false positives and negatives. Due to limited data availability, key inputs were informed by expert opinions, supported by published meta-analyses, public sources, and literature. Officially published Spanish prices were applied: EUR 2000 for [18F]-DCFPyL, [68Ga]-PSMA-11, and [18F]-PSMA-1007, and EUR 1144 for [18F]-FCH. Results: The use of [18F]-DCFPyL led to fewer unnecessary therapies; specifically, it led to 11,229 (74%) fewer than [68Ga]-PSMA-11, and 5180 (56%) and 7771 (66%) fewer than [18F]-FCH and [18F]-PSMA-1007, respectively. It achieved significant cost savings for repeated testing: EUR 15M (43%) versus [68Ga]-PSMA-11, EUR 37M (65%) versus [18F]-FCH, and EUR 27M (58%) versus [18F]-PSMA-1007. Cost savings for false positives were EUR 15M (50%) against [68Ga]-PSMA-11, EUR 22M (60%) versus [18F]-FCH, and EUR 29M (66%) compared with [18F]-PSMA-1007. The cost per correct diagnosis was reduced by EUR 198 (8%) compared with [68Ga]-PSMA-11 and EUR 377 (15%) relative to [18F]-PSMA-1007, while showing a EUR 635 (40%) increase compared with [18F]-FCH. Conclusions: [18F]-DCFPyL offers a cost-saving option for BCR detection within the Spanish National Healthcare System by reducing the number of unnecessary therapies, the cost of false positives, and repeat testing compared with alternative radiotracers. These improvements support the potential for better diagnostic outcomes and more informed downstream clinical decision-making.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
![Automated Preparation of [68Ga]Ga-3BP-3940 on a Synthesis Module for PET Imaging of the Tumor Microenvironment](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F68356.jpg&w=3840&q=50)
