Related Experiment Video
Updated: Feb 24, 2026

Hemodynamic Precision in the Neonatal Intensive Care Unit using Targeted Neonatal Echocardiography
Published on: January 27, 2023
Deep Learning-Based Automated Echocardiographic Measurements in Pediatric and Congenital Heart Disease
Platon Lukyanenko1, Sunil Ghelani2, Yuting Yang1
1Computational Health Informatics Program, Boston Children's Hospital, Department of Pediatrics, Harvard Medical School, Boston, MA, USA.
Background:
Echocardiography (echo) is a cornerstone of pediatric cardiology, yet access to expert interpreters is limited worldwide, particularly in low-resource and rural settings. Artificial intelligence (AI) offers a mechanism to broadly deliver expert-level precision and standardize measurements, yet AI for comprehensive automated measurements in pediatric and congenital heart disease (CHD) echo remains underdeveloped.
Methods:
We created EchoFocus-Measure, an AI platform that automatically extracts 18 quantitative parameters and 10 qualitative assessments from full echo studies. The method extends a multi-task, view-agnostic architecture (PanEcho) with a study-level transformer to prioritize diagnostically informative views. Training (80%) and internal testing (20%) were performed on echos from Boston Children's Hospital (BCH), with external evaluation on outside referral studies. Left ventricular ejection fraction (LVEF) was the primary endpoint.
Results:
The internal cohort included 11.4 million videos from 217,435 echos (60,269 patients; median age 8.5 years; median LVEF 61%), and external validation encompassed 289,613 videos from 3,096 echos (2,506 patients; median age 3.5 years; median LVEF 62%). For LVEF, EchoFocus-Measure exhibited a median absolute error (MAE) of 2.8% internally and 3.8% externally, maintaining accuracy across infants (MAE 3.2%) and complex CHD lesions (e.g., MAE 4.0% for L-loop transposition of the great arteries). EchoFocus-Measure improved upon the PanEcho benchmark (MAE 7.5% for infants; 13.1% for L-loop transposition). Discrepant case (>50th percentile error) adjudication of LVEF demonstrated that model errors (MAE 2.4%) were within human variability (MAE 3.7%). For qualitative measures, EchoFocus-Measure performed well internally (AUROC 0.88-0.95) and modestly externally (AUROC 0.73-0.86). Explainability analyses highlighted model focus on clinically appropriate echo views for LVEF estimation (apical four-chamber, parasternal short/long) and mitral regurgitation assessment (apical four-chamber color Doppler, parasternal short/long color Doppler).
Conclusions:
EchoFocus-Measure delivers rapid and reliable automated echo measurements across ages and lesions within diverse internal and real-world external cohorts, serving as a step toward scalable, global access to high-quality pediatric cardiovascular care.
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...