Accuracy and Reliability of Automated iPad Audiometry for Hearing Screening in Community Setting Compared with Gold
Wai Tsz Chang1,2, Christopher Xian Yao Liao3, Xiao Xin Chen1
1Department of Otorhinolaryngology, Head, and Neck Surgery, The Chinese University of Hong Kong, Hong Kong, China.
Abstract:
ImportanceEfficient and accurate tools for early detection of hearing loss are essential for reducing delays in diagnosis and treatment.ObjectiveTo determine the accuracy and reliability of Automated iPad Hearing Screening (AIHS) as a screening tool compared to a formal pure tone audiometry (PTA).DesignA parallel cross-sectional study.SettingTertiary referral center in Hong Kong.ParticipantsSeventy-nine adult patients (158 ears) aged from 28 to 87 who were diagnosed with hearing loss were included.Exposure or InterventionParticipants underwent the AIHS screening at 1, 2, 4, and 0.5 kHz in the right and left ears, respectively, prior to a formal PTA, focusing solely on air conduction thresholds.Main Outcome MeasuresSensitivity, specificity, positive predictive value, negative predictive value, and area under the receiver operating characteristic curve (AUC) for detecting hearing loss at 3 thresholds: >25, >40, and >60 dBHL. Intraclass correlation coefficient (ICC) and Bland-Altman analysis were used to assess agreement between AIHS and PTA.ResultsExcellent sensitivity and specificity of the AHIS were identified across 3 age groups and different hearing levels. The AUCs of AHIS were .917 (95% CI: .842-.993), .911 (.863-.960), and .968 (.942-.994) for thresholds over 25, 40, and 60 dBHL, respectively. ICC = .901 (.864-.927) and Bland-Altman analysis indicated good agreement between these 2 methods.ConclusionThe AIHS is a simple, intuitive, and portable screening test for hearing loss that can be repeated with high accuracy and reliability at relatively low cost.
More Related Videos
14:05Behavioral Assessment of Hearing in 2 to 4 Year-old Children: A Two-interval, Observer-based Procedure Using Conditioned Play-based Responses
Published on: January 23, 2017
06:04Systematic Hearing Performance Evaluation Process for Adolescents with Cochlear Implantation at Early Ages
Published on: March 24, 2023
Related Concept Videos
Pulse Assessment Sites
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: