Background:
Accurate esophageal cancer staging relies on 18F fluorodeoxyglucose positron emission tomography (18F FDG-PET), but its interpretation is complex and time-intensive. This diagnostic burden is exacerbated by significant workforce shortages in both radiology and surgery, thus necessitating automated support systems. The emergence of advanced large language models (LLMs) has raised expectations for their potential to fulfill this role in complex medical tasks.
Objective:
We evaluated the diagnostic accuracy of LLMs for staging esophageal cancer using 18F FDG-PET images, with a focus on their ability to assess lymph nodes (LNs; clinical N [cN]) and distant metastases (clinical M [cM]) for automated radiology reporting.
Methods:
This retrospective study included 120 consecutive adult patients who were diagnosed with esophageal squamous cell carcinoma and underwent 18F FDG-PET/computed tomography at Tohoku University Hospital between January 2019 and December 2021. Patients with prior treatment, nonsquamous cell carcinoma histology, or blood glucose levels ≥200 mg/dL were excluded. Frontal maximum-intensity projection positron emission tomography images were extracted, standardized, and analyzed along with information regarding the tumor location. Six LLMs (GPT-5, GPT-4.5, GPT-4.1, OpenAI-o3, -o1, and GPT-4 Turbo) and 4 blinded human evaluators (a nuclear medicine specialist, a gastrointestinal surgeon, and 2 radiology residents) assessed the presence of thoracic and abdominal LN metastases on a region-level basis and determined cN and cM staging on a patient-level basis. The model analyses were performed using the application programming interface in a zero-shot setting. Radiology reports served as the reference standard. Diagnostic agreement and accuracy were evaluated using Cohen κ and the Cochran Q test. Additionally, to account for the class imbalance in the dataset, the Matthews Correlation Coefficient was calculated as a robust metric for binary classification performance. Post hoc McNemar tests were performed with Bonferroni correction; statistical significance for pairwise comparisons was set at P<.0083 (adjusted from P<.05) using JMP Pro (version 18.0; SAS Institute Inc).
Results:
The average accuracy was 41/120 (34%) to 94/120 (78%) for LLMs and 72/120 (60%) to 102/120 (85%) for physicians, with significantly higher accuracy for physicians (P<.05) in the thoracic LN, abdominal LN, and cN stages. Interrater reliability was slight to fair for LLMs (κ: -0.07 to 0.25) and fair to substantial for physicians (κ: 0.27 to 0.74). Matthews Correlation Coefficient scores were consistently higher for physicians (0.28 to 0.75) than for LLMs (-0.07 to 0.32). Among the LLMs, GPT-5 demonstrated the highest overall accuracy, with newer LLMs showing improved diagnostic accuracy when compared with previous models in identifying abdominal LN metastases and cM staging, though they showed weaker consistency for cN staging. For example, in thoracic LN detection, GPT-5 achieved 76/120 (63%) accuracy, whereas other LLMs achieved 72/120 (60%) or lower accuracy.
Conclusions:
Although current LLMs have not yet reached physician-level accuracy in comprehensive staging, recent models show promise in assisting with specific diagnostic tasks.
More Related Videos
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
07:54Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET