Background:
ECG-based artificial intelligence may enable efficient prediction of incident heart failure (HF) risk to facilitate preventive efforts. Prior models are proprietary, with modest or inconsistent accuracy. We sought to develop and validate a generalizable and publicly available convolutional neural network to predict incident HF using the 12-lead ECG waveform (ECG-to-HF [ECG2HF]).
Methods:
We developed ECG2HF in 94 636 patients receiving longitudinal ambulatory care at Massachusetts General Hospital (MGH), and validated it in 3 test sets: MGH, Brigham and Women's Hospital (BWH), and Beth Israel Deaconess Medical Center (BIDMC), among 93 868 individuals aged 30 to 79 years without HF. HF events at 10 years were identified using a validated electronic health record-based natural language processing model. Discrimination was quantified using the area under the receiver operating characteristic curve. We then compared discrimination and net reclassification (at <10%, 10% to 20%, ≥20% 10-year risk categories) using ECG2HF versus the 15-component Pooled Cohorts Equations to Prevent HF score.
Results:
The test sets comprised MGH (13 954 individuals, 441 events, age 57±13 years, 48% women), BWH (54 396 individuals, 1809 events, age 57±13 years, 55% women), and BIDMC (25 457 individuals, 901 events, age 57±13 years, 53% women). Over 10 years, the cumulative risk of HF was 4.6% (95% CI, 4.1-5.0) in MGH, 5.0% (4.8-5.2) in BWH, and 4.4% (4.1-4.7) in BIDMC. ECG2HF discriminated 10-year incident HF in each test set (area under the receiver operating characteristic curve: MGH 0.86 [0.84-0.87]; BWH 0.85 [0.84-0.86]; BIDMC 0.84 [0.83-0.86]). Compared with the Pooled Cohorts Equations to Prevent HF, ECG2HF provided favorable discrimination (improvement in area under the receiver operating characteristic curve MGH/BWH 0.061 [0.025-0.097]; BIDMC 0.038 [-0.0096 to 0.086]) and net reclassification (NRI MGH/BWH 0.16 [0.077-0.24]; BIDMC 0.23 [0.10-0.35]) of 10-year HF risk.
Conclusions:
ECG2HF is a publicly available 12-lead ECG-based artificial intelligence model that discriminates the risk of future HF with favorable and consistent performance across 3 large health care samples from the northeastern United States. ECG2HF may enable efficient prioritization of high-risk individuals for HF-related preventive measures.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Cardiopulmonary Resuscitation III: AED Use
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...