Cardiac device motion tracking from kilovoltage projections during stereotactic arrhythmia radioablation
Wenjuan Xiong1, Doan Trang Nguyen2,3, Daryl Wilding-McBride1
1School of Health and Biomedical Sciences, RMIT University, Victoria, Australia.
Background And Purpose:
Cardiac and respiratory motion present a challenge to accurate dose delivery during stereotactic arrhythmia radioablation (STAR). This study investigated a motion tracking method using kilovoltage (kV) images on a gantry-mounted linear accelerator during STAR.
Materials And Methods:
An implantable cardioverter-defibrillator (ICD) lead tip was used for motion tracking. Planning computed tomography and cone beam computed tomography scans were analysed retrospectively on ten patients treated with STAR in RAdiosurgery for VENtricular TAchycardia (RAVENTA) (four patients underwent deep inspiratory breath-hold, two with free breathing, three under abdominal compression, and one using high frequency ventilation). A template-matching approach was developed to segment ICD lead tips in kV projections, with successful segmentation defined as a segmented position within 2 mm of the two-dimensional (2D) ground truth derived from manual annotations. A probability distribution function method was used to convert 2D coordinates to three-dimensional (3D) trajectories. 3D trajectories from the 2D ground truth were used to measure ICD lead tip displacements from its mean position. Differences between 3D trajectories from 2D ground truth and segmentations were analysed.
Results:
The median (range) 2D segmentation success rate was 85% (71-96%). Median (range) motion displacements were 1.4 (0.1-7.4) mm (left-right), 1.5 (0.1-10.4) mm (superior-inferior), and 0.8 (0.0-6.3) mm (anterior-posterior). The median (range) proportion of 3D estimations with errors below 2 mm in all axes was 78% (43-96%).
Conclusions:
ICD lead tip motion showed patient-specific variability. This study presented a potential 3D motion tracking method for ICD lead tips during STAR.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Holter Monitor: 24-Hour Monitoring
Dysrhythmias V: Evaluating Dysrhythmias