Related Experiment Video
Updated: Feb 26, 2026

Echocardiographic Assessment of the Right Heart in Mice
Published on: November 27, 2013
Comparative Evaluation of Three Transthoracic Echocardiographic Techniques for Cardiac Output and Stroke Volume
Lei Wang1, Da-Wei Wang1, Rui-Ming Xu1
1Department of Emergency, Beijing Tongren Hospital, Capital Medical University, Beijing, China.
Objective:
This study compared the accuracy of three transthoracic echocardiographic (TTE) techniques-fractional shortening (FS), left ventricular outflow tract velocity-time integral (LVOT/VTI), and Simpson's method-for measuring cardiac output (CO) and stroke volume (SV) in hemodynamically unstable patients (systolic pressure < 90 mmHg), using pulse index continuous cardiac output (PiCCO) as the reference.
Methods:
A retrospective analysis was conducted involving 12 patients admitted to an Emergency Intensive Care Unit between October 2023 and October 2024, who underwent a total of 54 echocardiographic examinations. The median length of hospital stay is 14 days. CO and SV values obtained using the three TTE methods as part of routine assessment were compared with simultaneous PiCCO measurements. The median number of examinations for patients is 4. Statistical analysis was performed using correlation methods.
Results:
All three TTE methods demonstrated the capability to estimate CO and SV. The VTI method showed the highest overall accuracy (CO-VTI vs. CO-PiCCO: r = 0.950, p< 0.001). Under reduced CO conditions, correlations between echocardiographic and PiCCO-derived measurements decreased for all methods; however, the VTI method maintained superior reliability (r = 0.606, p = 0.006). In contrast, the Simpson's method did not accurately reflect CO in this setting (SV-Simpson vs. SV-PiCCO: r = 0.408, p = 0.083). Notably, the performance of the VTI method remained consistent regardless of SV or heart rate variations (SV-VTI vs. SV-PiCCO: overall r = 0.970; with heart rate > 100 bpm, r = 0.946; with heart rate ≤ 100 bpm, r = 0.988).
Conclusion:
The LVOT/VTI method exhibits the highest accuracy and consistency for measuring SV and CO, making it the preferred non-invasive technique for hemodynamic evaluation in critically ill patients.
Related Concept Videos
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...