Related Experiment Video
Updated: Feb 26, 2026

Infrared Thermography for the Detection of Changes in Brown Adipose Tissue Activity
Published on: September 28, 2022
[Comparative analysis of the accuracy of determining the postmortem interval by single and dynamic thermometry of a
1Samara State Medical University, Samara, Russia.
Objective:
To compare the accuracy of determining the postmortem interval using the best methods of single and dynamic thermometry of a corpse in the presence of metrological errors and to find ways to increase it for methods of dynamic thermometry of a corpse.
Material And Methods:
A controlled comparative analysis of errors in determining the postmortem interval using C. Henssge methods and nonlinear programming was performed for one- and two-hour time intervals between measurements of cadaver temperature. The database of G.S.W. De Saram and co-authors, which contained data from 37 observations of standardized dynamic rectal thermometry, was used as research objects.
Results:
The results of determining the postmortem interval by dynamic postmortem thermometry due to an increase in the number of temperature measurements are more susceptible to the negative influence of metrological errors than estimates of methods based on single thermometry of a corpse. It is possible to increase the accuracy of dynamic thermometry methods by reducing body temperature measurement errors, increasing the time interval between them and reducing their number.
Conclusions:
The results of determining the postmortem interval by postmortem dynamic thermometry due to an increase in the number of temperature measurements are more susceptible to the negative influence of metrological errors than estimates of methods based on single thermometry of a corpse. It is possible to increase the accuracy of dynamic thermometry methods by reducing body temperature measurement errors, increasing the time interval between them and reducing their number.
More Related Videos
04:54Using a Combination of Indirect Calorimetry, Infrared Thermography, and Blood Glucose Levels to Measure Brown Adipose Tissue Thermogenesis in Humans
Published on: June 2, 2023
06:08Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging
Published on: May 5, 2011
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...