Performance evaluation of a flexible GAGG sheet for surface imaging of x-rays from computed tomography (CT) and
Seiichi Yamamoto1, Kohei Nakanishi2, Katsunori Yogo2
1Faculty of Science and Engineering, Waseda University, Japan.
Abstract:
A flexible scintillator sheet made of Ce-doped Gd3Al2Ga3O12(GAGG) powder mixed with a two-part silicone adhesive enabled high-intensity imaging of proton beams on complex surfaces; however, its effectiveness for x-ray imaging remained unclear. To investigate this, we tested surface imaging with the GAGG sheet for both x-rays from computed tomography (CT) system and high-energy x-rays from linear accelerator (LINAC). For imaging of x-ray beam from CT system, we irradiated a flexible GAGG sheet with 140 kV x-rays, positioning it on a patient bed or curved surface of a cylindrical phantom. The resulting light emission on the GAGG sheet was captured by a CMOS camera. For LINAC x-ray imaging, we irradiated the GAGG sheet with 6 MV x-rays, setting it on a flat phantom or a human head phantom, and again captured the emitted light using a CMOS camera. In both CT and LINAC x-ray imaging, the light produced on the GAGG sheet was successfully captured at intervals as short as 100 ms, enabling real-time tracking of beams. The light output from CT x-rays was more than 50 times higher than that of plastic scintillator, while the light output from LINAC x-rays was 1.2 times higher. Given its adaptability to complex surfaces and high light emission for x-rays as well as real-time imaging capability, the flexible GAGG sheet shows potential for efficient surface beam imaging in both CT and LINAC x-ray applications.
More Related Videos
10:18Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography
Published on: February 21, 2017
07:48High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
Published on: September 30, 2022
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Imaging