Studying Cavitation Enhanced Therapy
Published on: April 9, 2021
Ultrasound cavitation therapy: inducing tumor drug delivery and blood flow changes with clinical ultrasound tools
Connor Krolak1, Lance De Koninck1, Sherry Gu1
1Department of Bioengineering, University of Washington, Seattle, WA, USA.
Abstract:
Hepatocellular carcinoma (HCC), the fourth leading cause of cancer-related deaths, remains difficult to treat due to underlying liver disease, abnormal tumor vasculature, elevated interstitial fluid pressure (IFP), and immune suppression. We developed a theranostic approach using ultrasound cavitation with a clinical scanner and FDA-approved microbubbles to enhance vascular permeability and drug delivery in HCC. Acute experiments were performed in a subcutaneous HCC mouse model using a modified Philips EPIQ scanner and S5-1 phased-array probe under two conditions: moderate (1.6 MPa) and high (2.2 MPa) peak negative pressures. Contrast-enhanced ultrasound was acquired before, during, and after treatment, and vascular changes were quantified using a novel maximum intensity projection time area curve (MIP-TAC) analysis. Passive cavitation detection monitored microbubble activity. Doxorubicin extravasation, IFP (with a pressure catheter), and histology were assessed. Both ultrasound conditions induced transient tumor perfusion loss and reduced IFP without significant tissue damage or hemorrhage. The high-pressure treatment caused the greatest perfusion loss, whereas enhanced doxorubicin delivery occurred under moderate pressure. This result is likely due to excessive tumor perfusion loss in the high-pressure group, impeding further drug transport. These results demonstrate the feasibility of therapeutic cavitation with longer than previously evaluated acoustic pulses (1000 cycles) on a clinical scanner and clinically-approved microbubbles in HCC. Moderate-pressure cavitation maximized drug extravasation, underscoring the need to balance transient tumor perfusion loss with drug delivery. This clinically translatable strategy has potential to improve therapeutic outcomes in human HCC.
More Related Videos
09:05Generation and Quantitative Analysis of Pulsed Low Frequency Ultrasound to Determine the Sonic Sensitivity of Untreated and Treated Neoplastic Cells
Published on: July 22, 2015
08:02A High-Throughput Image-Guided Stereotactic Neuronavigation and Focused Ultrasound System for Blood-Brain Barrier Opening in Rodents
Published on: July 16, 2020
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...