Related Experiment Video
Updated: Feb 27, 2026

Combined Near-infrared Fluorescent Imaging and Micro-computed Tomography for Directly Visualizing Cerebral Thromboemboli
Published on: September 25, 2016
Experimental Characterisation of Differently Composed Thrombus Entities with Spectral-Detector-CT
Schekeb Aludin1, Agreen Horr1, Lars-Patrick Schmill1
1Department of Radiology and Neuroradiology, University Hospital of Schleswig-Holstein, 24105 Kiel, Germany.
None:
Background/Objectives: Thrombus composition influences the success of endovascular therapy in stroke, but conventional CT is limited in determining it. Spectral-detector-CT (SDCT) can apply material-decomposition and virtual monoenergetic (MonoE) imaging, which may provide a way to gain information on thrombus composition. This experimental study aimed to evaluate the differentiability of heterogeneous thrombi with variable red blood cell (RBC) content using SDCT. Methods: Ten thrombus entities with different compositions on RBC and plasma, thus fibrin content, were manufactured (volumetric RBC%/Plasma% = 90/10; 80/20; 70/30; 60/40; 50/50; 40/60; 30/70; 20/80; 10/90; 5/95) and scanned in an SDCT. Conventional Hounsfield-unit (HU) values, spectral electron density (ED), effective atomic number (Z-effective) and HU in MonoE maps ranging from 40- to 200 keV were evaluated for thrombus differentiation. Results: Conventional HU increased with RBC content, allowing us to differentiate the entities (p < 0.001). ED values also increased with RBC content and allowed for differentiation too (p < 0.001). Z-effective values showed no differences among the different entities (p > 0.05). Regarding the mass-attenuation curves from 40 to 200 keV the different thrombi showed a similar curve progression with highest HU values at 40 and lowest at 200 keV. The thrombi could be distinguished overall at each monoenergetic level by HU (p < 0.001 for each level). The absolute decrease in HU between 40 and 200 keV was thereby not significantly different between the different entities, but the relative decrease was, as it was more pronounced in thrombi with lower RBC content (p < 0.001). Conclusions: Spectral CT enables differentiation between thrombi with different RBC and fibrin contents by means of ED or analysis of the mass-attenuation curve. This offers alternative possibilities that go beyond characterisation based on CT-density alone. The additional inclusion of spectral parameters in thrombus diagnostics could therefore improve diagnosis and treatment.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Imaging Studies for Cardiovascular System V: CT

