Related Experiment Video
Updated: May 7, 2026

Field-Deployable Candidatus Liberibacter asiaticus Detection Using Recombinase Polymerase Amplification Combined with CRISPR-Cas12a
Published on: December 23, 2022
Ultrasensitive miRNA detection via magnetic bead-confined catalytic hairpin assembly enabling transcription-driven
Ming-Xi Pan1, Meng-Mei Lv2, Yin-Gang Nie1
1Key Laboratory of Environmentally Friendly Chemistry and Application of Ministry of Education; Key Laboratory for Green Organic Synthesis and Application of Hunan Province, College of Chemistry, Xiangtan University, Xiangtan, 411105, China.
Abstract:
The integration of CRISPR/Cas12a with catalytic hairpin assembly (CHA), a strategy that predominantly relies on CHA to generate dsDNA activators for direct Cas12a activation, has emerged as a powerful tool in molecular diagnostics. However, two major challenges remain: the strict protospacer adjacent motif (PAM) dependence of the dsDNA and background leakage from hairpin hybridization. Herein, we report a bead-confined platform that transcription mediates crRNA reassembly and template activation of Cas12a for ultrasensitive miRNA detection. The target-triggered CHA assembly dynamically constructed a T7 transcription template from three initially locked hairpins (H1, H2, and H3), which not only transcribed scaffold RNA but also hybridized with its own product to form a DNA/RNA complex that activates Cas12a. The integration of the split T7 promoter with CHA effectively suppressed background suppression and enhanced detection sensitivity. Additionally, the magnetic beads increase local concentration and reaction kinetics, collectively contributing to a substantially enhanced detection sensitivity. Moreover, a crRNA assembly strategy designed for transcription-powered Cas12a not only circumvents the conventional PAM-dependent dsDNA activation pathway of Cas12a but also enables self-supplied crRNA without requiring additional activators. We demonstrated that the biosensor exhibits exceptional sensitivity for miRNA-21 detection, achieving a limit of 65.3 aM. Furthermore, the practicality of this method was preliminarily confirmed through accurately quantifying target levels in cell lines and human serum. Our method presents a viable solution with transformative potential, designed to address complex challenges in contemporary diagnostic applications.
More Related Videos
10:16Author Spotlight: Development of Simplified CRISPR-Based Tests for Rapid Detection of Infectious Diseases
Published on: August 16, 2024
09:06MicroRNA Amplification and Recognition through Locked-nucleic-acid In situ Hybridization as a Novel Detection and Quantification Method
Published on: October 7, 2025