Related Experiment Video
Updated: Feb 28, 2026

Author Spotlight: Enhancing Vascular Function and Physical Capacity in Cardiovascular Disease Through Novel Interventions and NIRS Technology
Published on: March 22, 2024
Exploring haemoglobin Köln: a rare cause of pulse oximetry and arterial oxygen saturation discrepancy
Leshanth Uthayanan1, Rida Suleman1, Luke Green1
1Respiratory Medicine, George Eliot Hospital NHS Trust, Nuneaton, UK.
Abstract:
Pulse oximetry guides the management of respiratory conditions through non-invasively monitoring arterial oxygen saturation. Unstable haemoglobin variants may produce inaccurate readings. We describe a man in his 60s with chronic obstructive pulmonary disease admitted to hospital with a lower respiratory tract infection and pulmonary emboli. His pulse oximetry saturation was 88% on 3 L nasal cannula. However, an arterial blood gas (ABG) showed his oxygen saturation (sO2) at 96.7% and his partial pressure of carbon dioxide raised to 6.0 kPa (45.0 mm Hg). His oxygen was removed, and his pulse oximetry reading dropped to 79%-80%. A simultaneous ABG showed an sO2 of 91.3%, demonstrating ≈10% saturation gap in oxygen saturation between the pulse oximetry and ABG readings. Subsequent genetic testing confirmed haemoglobin Köln. We recommend performing an ABG and investigating for unstable haemoglobinopathies when the pulse oximetry and arterial oxygen readings are discordant. This is important for patients with respiratory diseases, as over-oxygenation can lead to decompensated type 2 respiratory failure.
More Related Videos
04:10Author Spotlight: Exploring Venous Waveforms for Non-Invasive Respiratory Monitoring in Pigs
Published on: March 8, 2024
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Oxygen Transport in the Blood
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...