Related Experiment Video
Updated: Feb 28, 2026

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
The Effect of Bone Substitutes for Low-Energy Comminuted Distal Radius Fractures amongst Elderly Women Treated with
Hirotaka Akezuma1,2, Ichiro Okano2, Takeshi Sakai1
1Department of Orthopedics, Showa University Northern Yokohama Hospital, Kanagawa, Japan.
Abstract:
Background: This study aimed to investigate whether the use of artificial bone substitutes during volar locking plate (VLP) fixation for intra-articular comminuted distal radius fractures in elderly women improves radiographic and clinical outcomes. Methods: A retrospective study was conducted on female patients aged ≥65 years with intra-articular comminuted distal radius fractures (AO/OTA types B3, C2 and C3) treated with VLPs between 2018 and 2022. Patients were categorised into groups based on the use of β-tricalcium phosphate (β-TCP) as a bone substitute. A propensity score (PS) matched comparison utilising inverse probability of treatment weight was conducted comparing patients receiving standard versus β-TCP augmentation during fixation. Clinical and radiographic outcomes were evaluated. The screw-joint surface distance was assessed as a radiographic parameter indicative of optimal distal screw positioning adjacent to the subchondral bone. Results: The mean follow-up period was 9.9 months (range: 6-35 months). After PS matching, each group included 35 patients with comparable baseline characteristics. The screw-joint surface distance was significantly lower in the bone substitute group, indicating closer distal screw placement. However, at final follow-up, no significant differences were observed between the groups in radiographic or clinical outcomes. These results were consistent in inverse probability of treatment weighting (IPTW)-adjusted regression analysis. Conclusions: Closer placement of screws near the joint was observed in the bone substitute group, possibly reflecting improved intraoperative stability, but was not significantly associated with the prevention of postoperative correction loss or other clinical outcomes. Since clinical outcomes were similarly good regardless of its usage, artificial bone substitute may not be necessary for low-energy comminuted intra-articular fractures in elderly women. Further studies are warranted to determine its potential benefit in cases involving severe metaphyseal voids or joint instability. Level of Evidence: Level III (Therapeutic).
More Related Videos
09:26An Efficient and Reproducible Protocol for Distraction Osteogenesis in a Rat Model Leading to a Functional Regenerated Femur
Published on: October 23, 2017
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
Related Concept Videos
Bone Disorders
Bone deposition is also affected by the levels of sex hormones like estrogen and testosterone that promote osteoblast activity and bone matrix synthesis. When the level of these hormones decreases due to aging, it causes a reduction in bone deposition. As a result, bone resorption by osteoclasts...
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...