Clinical Validation of rPPG-Enabled Contactless Pulse Rate Monitoring Software in Cardiovascular Disease Patients

Jing Wei Chin1, Po Him David Chan1, Shutao Chen1

  • 1Department of Clinical AI, PanopticAI, Hong Kong SAR, China.

PubMed

Insights

Remote photoplethysmography (rPPG) accurately measures pulse rate in cardiovascular disease (CVD) patients using video, offering a contactless solution for remote monitoring and early detection of health deterioration.

Area of Science:

  • Biomedical Engineering
  • Cardiology
  • Medical Imaging

Background:

  • Cardiovascular disease (CVD) is a leading global cause of death.
  • There is a need for continuous, unobtrusive patient monitoring solutions.
  • Remote photoplethysmography (rPPG) offers a contactless approach to vital sign measurement.

Purpose of the Study:

  • To clinically validate the accuracy of rPPG for pulse rate (PR) measurement in patients with CVD.
  • To compare rPPG-derived PR with traditional electrocardiogram (ECG) measurements.
  • To assess the influence of various factors on rPPG accuracy.

Main Methods:

  • 50 adults with confirmed CVD were enrolled.
  • Synchronized facial video, ECG, and photoplethysmography (PPG) signals were recorded during a 6-minute session.
  • PR was derived from 25-second video segments using rPPG software and compared to ECG-derived PR.

Main Results:

  • rPPG-derived PR demonstrated strong agreement with ECG (Pearson correlation of 0.962).
  • Mean absolute error was 1.061 bpm, with a root-mean-squared error of 2.845 bpm.
  • Demographic, environmental, or CVD factors showed minimal influence on rPPG accuracy.

Conclusions:

  • rPPG is an accurate contactless method for PR monitoring in CVD patients.
  • This technology supports remote patient monitoring and early detection of deterioration.
  • Further validation is needed for irregular rhythms, diverse populations, and additional vital signs.
Abstract

Related Concept Videos

Pulse rhythm01:30

Pulse rhythm

Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
1.5K
Assessment of radial pulse01:11

Assessment of radial pulse

Assessment of Radial Pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
1.6K
Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
3.8K
Assessment of apical radial pulse01:25

Assessment of apical radial pulse

Apical-Radial (A-R) Pulse Assessment
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
1.4K
Special considerations while measuring pulse01:13

Special considerations while measuring pulse

Assessing a patient's pulse is a fundamental skill in healthcare, but certain situations require special attention:
1000
Pulse01:16

Pulse

When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
2.4K