Related Experiment Video
Updated: Feb 28, 2026

Quantification of the Immunosuppressant Tacrolimus on Dried Blood Spots Using LC-MS/MS
Published on: November 8, 2015
Clinical Application of Microvolume LC-MS/MS for Therapeutic Drug Monitoring of Immunosuppressants in Solid-Organ
Daiki Iwami1, Natsuka Kimura2, Sho Nishida1
1Division of Renal Surgery and Transplantation, Department of Urology, Jichi Medical University, Shimotsuke 329-0498, Japan.
Abstract:
Background/Objectives: Therapeutic drug monitoring (TDM) is essential for optimizing immunosuppressive therapy in solid-organ transplant recipients by maintaining efficacy, while minimizing adverse effects. However, conventional TDM relies on venous sampling and separate assays for tacrolimus (TAC) in whole blood and mycophenolic acid (MPA) in plasma, thereby increasing patient burden and procedural complexity. To address these limitations, we investigated the clinical utility of a microvolume, liquid-phase microsampling device (MSW2™) in combination with liquid chromatography-tandem mass spectrometry (LC-MS/MS). Methods: We established and applied an LC-MS/MS method for simultaneous quantification of TAC, MPA, and mycophenolic acid β-D-glucuronide (MPAG) using only 2.8 µL of whole blood collected with MSW2™, which eliminates drying or extraction steps. Hematocrit-based correction was applied to estimate plasma MPA concentrations from whole-blood measurements. The method was evaluated in 60 renal transplant recipients with paired venous samples for comparison. Analytical performance was assessed using regression, Bland-Altman analyses, predictive metrics, and stability testing under different storage conditions. Results: Microsampled and venous concentrations were strongly correlated (R2 > 0.95). Estimated plasma MPA concentrations derived from whole blood closely approximated plasma concentrations (bias < 5%). Reducing the sample volume from 5.6 µL to 2.8 µL improved precision and increased the success rate of blood collection from 72.9% to 94.0%. All analytes remained stable for up to 72 h at ≤25 °C. Conclusions: This approach enables accurate, simultaneous quantification of multiple immunosuppressants from trace blood volumes. By reducing sampling burden and simplifying logistics, it provides a clinically feasible and patient-centered strategy for precision TDM, supporting broader implementation of limited sampling strategies and expanding applicability to pediatric, home-based, and telemedicine settings.
More Related Videos
09:58Spatial Quantification of Drugs in Pulmonary Tuberculosis Lesions by Laser Capture Microdissection Liquid Chromatography Mass Spectrometry LCM-LC/MS
Published on: April 18, 2018
18:48In Vitro and In Vivo Assessment of T, B and Myeloid Cells Suppressive Activity and Humoral Responses from Transplant Recipients
Published on: August 12, 2017
Related Concept Videos
Therapeutic Drug Monitoring: Drug Analysis Methods
Therapeutic Drug Monitoring: Affecting Factors
Therapeutic Drug Monitoring: Overview and Classification