In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
Published on: July 2, 2021
Optimising Camera-ChArUco Geometry for Motion Compensation in Standing Equine CT: A CT-Motivated Benchtop Study
Cosimo Aliani1, Cosimo Lorenzetto Bologna2, Piergiorgio Francia1
1Department of Information Engineering, University of Florence, Via di Santa Marta 3, 50139 Florence, Italy.
None:
Standing equine computed tomography (CT) acquisitions are susceptible to residual postural sway, which can introduce view-inconsistent motion and degrade image quality. External optical tracking based on ChArUco fiducials is a promising, low-cost strategy to enable projection-wise motion compensation, yet quantitative guidance on how camera-marker geometry affects pose-estimation performance remains limited. This CT-motivated benchtop study characterizes how the relative camera-ChArUco configuration influences both the accuracy (bias with respect to ground truth) and the precision (repeatability) of pose estimates obtained from RGB images using OpenCV ChArUco detection and reprojection-error minimization to estimate the rigid camera-to-board transformation. Controlled experiments systematically varied acquisition protocol (continuous repeated estimates at fixed pose versus cyclic repositioning), viewing angle over a wide angular range at two working distances, and camera-to-board distance over multiple depth settings. Ground truth for angular configurations was defined by a stepper-motor rotation stage, while distance ground truth was obtained by ruler measurements. Performance was summarized via mean absolute error and standard deviation across repeated measurements, complemented by variance-based statistical testing with multiple-comparison correction. Cyclic repositioning did not yield evidence of increased variability relative to continuous acquisitions, supporting view-by-view sampling. Viewing angle induced a consistent accuracy-precision trade-off for rotations: frontal views minimized mean error but exhibited higher variability, whereas oblique views reduced jitter at the expense of increased bias. Increasing working distance reduced repeatability, most prominently for depth-related components. Overall, these findings provide pre-clinical guidance for selecting camera/marker placement (moderately oblique viewpoints, limited working distance, sufficient image footprint) before in-scanner and in-vivo validation for standing equine CT motion compensation.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT