Related Experiment Video
Updated: Feb 28, 2026

Robotic Taj Mahal Hepatectomy for Hilar Cholangiocarcinoma
Published on: July 14, 2022
Utilization of an Umbilical Hernia as a Camera Port in Robot-Assisted Total Hysterectomy: A Case Report
Shohei Wakisaka1, Hiroharu Kobayashi1, Aimi Oda1
1Gynecology, Seirei Hamamatsu General Hospital, Hamamatsu, JPN.
Abstract:
We report a case of robot-assisted total hysterectomy in which an umbilical hernia was utilized as the camera port. A 43-year-old obese woman with atypical endometrial hyperplasia and an incidental umbilical hernia underwent surgery. After resection of omental contents from the hernia sac, a balloon trocar was placed in the umbilicus and used as a camera port. The hysterectomy was safely completed, and hernia repair followed. To our knowledge, only limited reports have described this approach in robotic surgery. This case highlights the technical feasibility of using an umbilical hernia for robotic port placement, though careful postoperative monitoring is warranted due to the risk of recurrence without mesh repair.