Characterisation of interrelations among myocardial work parameters in patients with hypertrophic cardiomyopathy:
Viktória Nagy1, Gergely Rácz1, Krisztina Boda2
1Division of Non-Invasive Cardiology, Cardiology Centre, Department of Internal Medicine, University of Szeged, Szeged, Hungary.
Background/Objectives:
In recent years, novel echocardiographic parameters, known as myocardial work (MW) parameters, have been introduced into clinical practice for the assessment of contractile function. This study aimed to provide a technical characterization of the interrelations among these MW parameters and evaluate their differences between patients with non-obstructive (nHCM) and obstructive hypertrophic cardiomyopathy (oHCM).
Patients And Methods:
One-hundred-eighteen patients with HCM, including 68 nHCM and 50 oHCM patients were assessed. Global longitudinal strain (GLS) and derived global MW parameters-including global work index (GWI), global constructive work (GCW), global wasted work (GWW), and global work efficiency (GWE)-were determined by 2D-speckle tracking echocardiography.
Results:
In all HCM cohorts, GLS demonstrated a strong, significant correlation with GWI and GCW (r: -0.619 to -0.818), whereas the correlation between GLS and GWW was considerably weaker (r: 0.320 to 0.373), consistent in both univariate correlation and multiple regression analyses. A strong, significant correlation was observed between GWI and GCW, and a significant correlation existed between GWW and GWE. Within HCM subgroups characterized by increasing left ventricular outflow tract (LVOT) gradients, GWI/GCW values exhibited "pseudonormalization" in the obstructive HCM groups, due to the offsetting effects of the nominal decrease in GLS and the nominal increase in LVOT gradient. In contrast, GWW values increased gradually with increasing LVOT gradients, and the difference compared to controls was significant even in the HCM group with LVOT gradients <10 mmHg.
Conclusions:
Given the strong correlation between GLS and GWI/GCW, it is probable that changes in GLS would result in corresponding changes in GWI/GCW, potentially limiting the incremental discriminatory value of these parameters beyond GLS. GWW appears to be the most independent MW parameter from GLS in patients with hypertrophic cardiomyopathy as it weakly correlates with GLS, unlike GWI/GCW.
Related Concept Videos
Cardiomyopathy III: Hypertrophic Cardiomyopathy
Pathophysiology of Cardiac Performance
Cardiomyopathy V: Interprofessional Care
Cardiomyopathy I: Introduction and Classification
Cardiomyopathy IV: Restrictive Cardiomyopathy
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...