Related Experiment Video
Updated: Feb 28, 2026

Electrochemical Preparation of Poly3,4-Ethylenedioxythiophene Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
Preparation of graphdiyne for efficient capacitive extraction of U(VI) from water samples
Xuena Chen1, Yuang Liu1, Zitong Song1
1School of Materials and Chemical Engineering, Anhui Province International Research Center on Advanced Building Materials, Anhui Jianzhu University, No. 292, Ziyun Road, Hefei 230601, China. zhaodlin@126.com.
Abstract:
In this work, a one-step hydrothermal condensation process was used to prepare graphdiyne (GDY), which was then used as an electrode material for the capacitive extraction of U(VI) from wastewater. The synthesized GDY exhibited a multilayered lamellar structure, which provided abundant active sites for U(VI) adsorption. Additionally, the average pore diameter of GDY is 3.8 nm, and its specific surface area can attain 60.7 m2·g-1. The electro-adsorption of U(VI) onto the GDY electrode is influenced by applied voltage, competing metal ions, reusability, and pH, and conforms to pseudo-second-order kinetics. At 298.15 K and an applied potential of 1.2 V, the removal efficiency of U(VI) by GDY reached approximately 80.7% within 3 h. After six consecutive cycles, the removal efficiency showed only a 7.9% decrease compared to the initial cycle. Simultaneously, the removal efficiency of GDY for U(VI) significantly surpassed that of other coexisting metal ions, reaching 57.9%, thereby indicating that GDY exhibited a certain selectivity toward U(VI). Furthermore, the extent of redox reactions in GDY had significant variation depending on the applied voltage and scan rate. These studies suggest that GDY exhibits potential application value in the treatment of uranium-containing wastewater.
More Related Videos
09:15Iridium Oxide-reduced Graphene Oxide Nanohybrid Thin Film Modified Screen-printed Electrodes as Disposable Electrochemical Paper Microfluidic pH Sensors
Published on: November 22, 2016
11:18Manufacturing of a Nafion-coated, Reduced Graphene Oxide/Polyaniline Chemiresistive Sensor to Monitor pH in Real-time During Microbial Fermentation
Published on: January 7, 2019
Related Concept Videos
UV–Vis Spectrometers
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetric Techniques: Linear-Scan (E vs Time)
Capillary Electrophoresis: Instrumentation