Safety and Efficacy of Temperature-Guided Radiofrequency Ablation for Ventricular Tachycardia: A Multicenter Study
Paolo Compagnucci1, Henry D Huang2, Marco Bergonti3
1Cardiology and Arrhythmology Clinic, University Hospital "Azienda Ospedaliero-Universitaria delle Marche," Ancona, Italy.
Background:
A catheter platform allowing power- and temperature-controlled ablation (temperature-guided ablation) has recently been introduced. Clinical outcomes after ventricular tachycardia (VT) ablation using this technology remain uncertain.
Objectives:
The goal of this study was to evaluate the safety and efficacy of temperature-guided VT ablation and compare the findings vs those from standard power-controlled ablation.
Methods:
This multicenter cohort study enrolled consecutive patients undergoing temperature-guided VT ablation using the QDOT MICRO catheter (Biosense Webster) at 8 referral centers in Europe and the United States (2021-2024). For comparison, a multicenter cohort of patients receiving power-controlled ablation with the THERMOCOOL SMARTTOUCH or SMARTTOUCH SurroundFlow (Biosense Webster) catheters was also included. The primary safety endpoint was procedure-related complications. The primary efficacy endpoint was sustained VT/ventricular fibrillation recurrence during long-term follow-up, assessed in the overall cohort and in propensity score-matched patients.
Results:
The study included 286 patients: 109 treated with temperature-guided ablation and 177 with power-controlled ablation. Ischemic cardiomyopathy was the predominant VT substrate (n = 125 [44%]); approximately one-half presented with electrical storm. Propensity score matching based on baseline clinical data yielded 101 pairs. Procedure-related complications were significantly lower with temperature-guided ablation (temperature-guided: n = 3 [3%]; power-controlled: n = 23 [13%]; P = 0.003), a result that remained significant after matching (temperature-guided: n = 3 [3%]; power-controlled: n = 12 [12%]; P = 0.028) and excluding vascular complications (temperature-guided: n = 1 [1%]; power-controlled: n = 14 [8%]; P = 0.012). Use of temperature-guided ablation was associated with lower odds of nonvascular complications in multivariable analysis (adjusted OR: 0.095; P = 0.028). Over a median follow-up of 24 months, VT/ventricular fibrillation recurrence rates were similar between groups in both overall (log-rank test, P = 0.570) and matched (log-rank test, P = 0.850) cohorts. Subgroup analyses showed no signal of heterogeneity.
Conclusions:
In this multicenter VT ablation registry, a novel temperature-guided ablation modality showed favorable safety and efficacy relative to power-controlled ablation.
More Related Videos
06:25Cooling or Warming the Esophagus to Reduce Esophageal Injury During Left Atrial Ablation in the Treatment of Atrial Fibrillation
Published on: March 15, 2020
04:58Reduced Procedure Time and Variability with Active Esophageal Cooling During Radiofrequency Ablation for Atrial Fibrillation
Published on: August 25, 2022
Related Concept Videos
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System V: CT
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
Coronary Artery Disease IV: Preventive Measures
Acute Coronary Syndrome III: Diagnostic Studies