Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Pulse rhythm01:30

Pulse rhythm

Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Errors occurring during blood pressure monitoring01:25

Errors occurring during blood pressure monitoring

Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Rectangular Pulse Three-Hour Repetitive Transcranial Magnetic Stimulation Treatment for Major Depressive Disorder: A Pilot Trial.

Neuromodulation : journal of the International Neuromodulation Society·2026
Same author

Two-Step 3D Microphone Array Fusion Algorithm to Enhance Sound Source Location Measurements.

Sensors (Basel, Switzerland)·2026
Same author

Artificial intelligence-enabled histological analysis in pre-clinical respiratory disease models: a scoping review.

European respiratory review : an official journal of the European Respiratory Society·2026
Same author

Deep Learning Analysis of Prenatal Ultrasound for Identification of Ventriculomegaly.

Ultrasound in medicine & biology·2026
Same author

Sound and Vibration Exposure During Fixed-Wing Aircraft Neonatal Patient Transport.

Air medical journal·2026
Same author

Automated mean linear intercept measurement: quantifying bias and parameter sensitivity in lung morphometry.

Physiological measurement·2025

Related Experiment Video

Updated: Jul 22, 2026

A Swin Transformer-Based Model for Thyroid Nodule Detection in Ultrasound Images
04:23

A Swin Transformer-Based Model for Thyroid Nodule Detection in Ultrasound Images

Published on: April 21, 2023

Toward robust automated cardiovascular arrhythmia detection using self-supervised learning and 1-dimensional vision

Mitchell Chatterjee1, Adrian D C Chan2, Majid Komeili3

  • 1School of Computer Science, Carleton University, Ottawa, K1S 5B6, Canada. mitchellchatterjee@cmail.carleton.ca.

Scientific Reports
|March 3, 2026
PubMed
Summary

Self-supervised learning with Masked Patch Modelling (MPM) enhances arrhythmia detection from electrocardiogram (ECG) data. PatchECG, a novel 1D Transformer model, achieves state-of-the-art results efficiently, improving automated cardiovascular disease diagnosis.

Keywords:
Cardiac arrhythmiaDeep learningElectrocardiographyMedical diagnosisMedical signal classificationSelf-supervised learning

More Related Videos

Automatic Surgery in Transcatheter Aortic Valve Replacement Using Augmented Reality
07:46

Automatic Surgery in Transcatheter Aortic Valve Replacement Using Augmented Reality

Published on: August 9, 2024

Related Experiment Videos

Last Updated: Jul 22, 2026

A Swin Transformer-Based Model for Thyroid Nodule Detection in Ultrasound Images
04:23

A Swin Transformer-Based Model for Thyroid Nodule Detection in Ultrasound Images

Published on: April 21, 2023

Automatic Surgery in Transcatheter Aortic Valve Replacement Using Augmented Reality
07:46

Automatic Surgery in Transcatheter Aortic Valve Replacement Using Augmented Reality

Published on: August 9, 2024

Area of Science:

  • Artificial Intelligence
  • Biomedical Engineering
  • Cardiology

Background:

  • Cardiovascular diseases are a leading global cause of mortality.
  • Electrocardiogram (ECG) monitoring is increasingly accessible for passive arrhythmia detection.
  • Challenges in ECG analysis include class imbalance and noise, hindering traditional machine learning models.

Purpose of the Study:

  • To leverage self-supervised learning on large-scale unlabeled ECG data for improved arrhythmia detection.
  • To introduce and evaluate PatchECG, a novel 1D Transformer model, for ECG analysis.
  • To enhance model performance, efficiency, and robustness against common ECG data issues.

Main Methods:

  • Utilized Masked Patch Modelling (MPM) for self-supervised pre-training on 8.2 million unlabeled ECGs.
  • Developed PatchECG, a 1D Transformer architecture, for various ECG classification tasks.
  • Fine-tuned PatchECG on standard datasets (e.g., PTB-XL) and a large, high-quality multi-label dataset.

Main Results:

  • PatchECG achieved state-of-the-art performance on benchmark datasets, setting new records on a large multi-label dataset.
  • The model demonstrated a 5x increase in computational efficiency and a 14x increase in model capacity compared to existing methods.
  • PatchECG outperformed a state-of-the-art 2D vision Transformer (HeartBEiT) and showed a 2% improvement in handling data challenges like class imbalance and noise.

Conclusions:

  • Self-supervised learning, particularly with PatchECG, significantly advances automated arrhythmia detection.
  • The PatchECG model offers a computationally efficient and highly effective solution for analyzing ECG data.
  • This approach holds substantial potential for improving cardiovascular disease diagnosis and patient outcomes through automated monitoring.