Related Experiment Video
Updated: May 1, 2026

A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
State-of-the-art wearable sensors for cardiovascular health: a review
Hongwei Xie1,2, Longpeng Yang1, Binbin Jiang1,2
1School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu, China.
Abstract:
Wearable cardiovascular monitoring systems integrate advanced sensing technologies to provide real-time, personalized, and noninvasive healthcare through continuous monitoring and early warning capabilities, representing significant progress in accuracy, personalization, and connectivity. This review summarizes recent advances in wearable physical sensors, imaging technologies, and biochemical devices tailored for cardiovascular health monitoring, explores developments in early warning and closed-loop systems, and discusses future research directions and associated challenges.
More Related Videos
06:58An Application for Pairing with Wearable Devices to Monitor Personal Health Status
Published on: February 3, 2022
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of the Cardiovascular System I: Subjective Data
Initial Enquiry
Ask the patient about their primary concern and thoroughly explore all reported symptoms.
Medical History
Investigate past illnesses affecting the cardiovascular system, such as angina, anemia, rheumatic fever, congenital heart disease, stroke, thrombophlebitis, dysrhythmias, varicosities
Inquire about symptoms...
Holter Monitor: 24-Hour Monitoring