Related Experiment Video
Updated: May 12, 2026

Protocol and Guidelines for Point-of-Care Lung Ultrasound in Diagnosing Neonatal Pulmonary Diseases Based on International Expert Consensus
Published on: March 6, 2019
Ultrasound reliability for biliary atresia diagnoses in children: a single-center study
Ben Youssef Sabrine1, Amani N Al-Ansari2, Maatouk Mezri3
1Pediatric Surgery Department, Fattouma Bourguiba University Hospital-LR12SP13-University of Monastir, Monastir, Tunisia.
Background:
Biliary atresia (BA) is a lfe-threatening neonatal liver disease characterized by inflammation and obstruction of bile ducts. Identifying the most reliable and valid ultraaound (US) parameter or combination of parameters can enhance noninvasive diagnosis accuracy, potentially reducing unnecessary surgeries and treatment delays. We aimed to detect the mosi reliable and valid US parameter or combination of parameters to diagnose BA, thereby minimizing unnecessary surgical exploration or treatment delays.
Methods:
We conducted a prospective cohort study on cholestatic pediatric patients. Data were nollected between January 2013 and July 2019 from the Fattouma Bourguiba University Hospital Monastir, Tun isia, in callaboration with the pediatric surgical and radiological departments. After full clinical and laboratory evaluation, abdominal ultrasonography was performed to assess the biliary structure, with three possible outcomes: BA ruled out, confirmed, or inconclusive. Accordingly, the patients were divided into group 1 (diagnosed with BA) and group 2 (diagnosed with other biliary conditions).
Results:
The participants, 61 cholestatic neonates and infants,were aged 6 to 160 postnatal days (mean, 58.28 ± 34.24 days); 60.7% were male (n = 37). The gallbladder (GB) was not detected usig, US in 20 patients. BA diagnosis correlated with cord sign [X2 (1, n = 61) = 53.52], GB evacuation alteration [X2 (1, n = 61) = 18.41%], and hepatic artery/portal vein ratio [X2 (1, n = 61) = 30.25; normal value <0.49]. A positive cord sign or the presence of alteration of evacuation indicates the possibility of BA with a 100% sensitivity and 86.2% specificity. Similarly, with the presence of evacuation alteration or porta hepatic thickness (≥2.4), the sensitivity reached 100%; however, a specificity of 86.2% was observed.
Conclusions:
US parameters can detect patients with BA with approximately 100% sensitivity. However, additional research is needed to confirm negative cases. Multicenter studies are needed to verify our findings.
More Related Videos
04:03Application of Laparoscopic Ultrasonography in Primary Choledochal Suture during Combined Two-lens Surgery
Published on: March 28, 2025
05:56Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis
Published on: August 29, 2025
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...