Accuracy of Noninvasive Hemoglobin and Venous Blood Gas Hemoglobin Measurements in Comparison With the Laboratory
Marwa M Elmaghrabi1,2, Afrah Alatifi3, Najla Alsoofi4
1Botany and Microbiology Department, College of Science, King Saud University, Riyadh, SAU.
Abstract:
Background Rapid and accurate hemoglobin (Hb) measurement is crucial in Intensive Care Unit (ICU) patients for timely management of anemia and transfusion decisions. Noninvasive hemoglobin monitoring (SpHb) offers continuous assessment, while venous blood gas hemoglobin (VBGHb) provides point-of-care measurement. This study aimed to evaluate the absolute and trend accuracy of SpHb and VBGHb compared to standard laboratory hemoglobin (LabHb) in ICU patients. Methods Twenty patients in the ICU were enrolled. Hemoglobin was measured using SpHb, VBGHb, and LabHb. Absolute accuracy was assessed using Bland-Altman analysis, and correlation between methods was evaluated with Pearson correlation. Trend accuracy was assessed with modified Bland-Altman plots. Results A total of 79 samples were collected. SpHb demonstrated a mean bias of -0.0557 gm/dL (95% limits of agreement: -0.5614 to 0.4499) relative to LabHb, while VBGHb showed a larger bias of -0.4734 gm/dL (-2.8312 to 1.8844). SpHb had a strong correlation with LabHb (r = 0.978, p < 0.001), whereas VBGHb showed a moderate correlation (r = 0.506, p < 0.001). Trend analysis revealed a mean trend bias of -0.0102 gm/dL for SpHb (limits -0.6317 to 0.6113), compared with 0.0136 gm/dL for VBGHb (-3.5733 to 3.5461). Conclusions We concluded that SpHb demonstrated acceptable absolute and trend accuracy, as well as excellent correlation with LabHb, providing an easy, feasible, and accurate solution for Hb measurement in the ICU. Future studies should assess its impact on transfusion practices and patient outcomes.
More Related Videos
07:10Measurement of the Hepatic Venous Pressure Gradient and Transjugular Liver Biopsy
Published on: June 18, 2020
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to...